MAINTENANCE INSTRUCTIONS
Replacing the Drain Valve
1) Shut off the water supply.
2) Flush the toilet to remove the water inside the tank.
3) Remove the tank lid and place somewhere safe.
NOTE:
Before removing anything from the tank,
note the placement of the drain valve, chain and
refill tube.
4) Unhook the refill tube from the overflow tube of the
drain valve.
5) Unhook the chain from the trip lever.
6) Uninstall the tank (refer to the toilet installation
manual).
7) Remove the drain valve body from the tank.
8) Replace the drain valve in the same position as the
former drain valve.
9) Hand tighten the mounting nut of the drain valve
and use a wrench to tighten another 3/4 turn.
10) Reinstall the tank onto the bowl and place the
chain and refill tube the same way as it was for the
former drain valve.
11) Turn the water supply back.
12) Check for any leakage after the tank has been
filled.
No CEFIONTECT®
With CEFIONTECT®
WHAT IS CEFIONTECT®?
CEFIONTECT® CLEANING INSTRUCTIONS
CEFIONTECT® is TOTO’s super-smooth permanent glaze that prevents debris
from sticking to surfaces. Products with the letter “G” in the number have the
CEFIONTECT® glaze. This glaze, along with regular cleaning, will help keep your
TOTO product in pristine condition.
NOTE:
For best results to keep your Toto product with CEFIONTECT® clean:
• Lavatory: Use a mild dish detergent with a clean, soft cloth.
• Toilet: Use a gel based cleaner with a soft bristled-plastic brush.
•
Don't use
cleaners, polishing powders or detergents that have gritty or
coarse particles.
•
Don't use
bleach, chemical thinners or products that have acid or
alkaline detergents listed as ingredients.
•
Don't use
metal scrub brushes or steel wool.
Following these instructions will ensure that your TOTO product with the
CEFIONTECT® glaze will always stay intact, keeping your product like new