The Terminal Box provides easy, reliable connections for splicing wires and 
cables. All connections are housed in a weather-resistant enclosure. The termi-
nal box can simplify and speed up the task of wiring the weather station sen-
sors, sensor interface module (SIM), and communication lines.

 

Note:

 

The terminal blocks in the Terminal Box are rated for 300V, 10A and are intended for 26-16 AWG 

 

(.08-1.5 mm) wire. When wiring, all applicable building and electrical codes must be followed.

 

When connecting shielded cables to shielded cables, connect each colored wire 
to the same colored wire on the extension cable (or other cable). In twisted-pair 
cables, all black wires are ground and may be shorted together.

When connecting standard cables to standard cables, you may also connect 
each colored wire to the same colored wire on the extension cable (or other 
cable). In some cases, however, wires may be combined in order to use fewer 
terminals on the terminal block. Consult the table below:

 

S

 

ENSOR

 

W

 

IRES

 

 

 

IN

 

 

S

 

TD

 

. C

 

ABLE

 

W

 

IRES

 

 

U

 

SED

 

N

 

OTES

 

 

 

FOR

 

 S

 

TANDARD

 

 C

 

ABLES

 

Rain Collector

4

2

Twist RED and BLACK as one wire and GREEN and YELLOW as
another wire.

Temp/Hum Sensor

6

5

Twist RED and BLACK as one wire (ground).

Temp Sensor

4

2

Twist RED and BLACK as one wire (ground). Ignore GREEN.

UV/Leaf Wetness Sensor

6

3

Twist RED and BLACK as one wire (ground). Ignore GREEN and
BLUE.

Solar Radiation Sensor

4

3

Twist RED and GREEN as one wire (ground).

Anemometer

4

4

SIM/Junction Box Cable

8

8

Summary of Contents for Terminal Box

Page 1: ...ther cable In twisted pair cables all black wires are ground and may be shorted together When connecting standard cables to standard cables you may also connect each colored wire to the same colored w...

Page 2: ...components before continuing Terminal Box with Terminal Blocks Two 8 x 19 mm Self Threading Screws TOOLS AND MATERIALS NEEDED You may need some of the following tools and materials in order to install...

Page 3: ...ng down Note You may install the wires through the grommet and into the terminal blocks before or after mounting the Terminal Box 1 Hold the Terminal Box against the mounting surface and mark the loca...

Page 4: ...to the box by passing them up through the grommets at the bot tom of the box If routing cable to the top terminal block you may route cables either under the metal plate to which the terminal blocks a...

Page 5: ...ng strip next to the terminal insert the exposed wire into the opening created on the side of the terminal and release the spring strip When you release the spring strip the wire s will be held in pla...

Page 6: ...e the wire assignments for the terminal blocks before you remove the modular connector at the end of the standard cable To do this hold the standard cable latch lever upward facing the terminal block...

Page 7: ...Connecting to the Terminal Block Page 7...

Page 8: ...Davis Instruments Part Number 7395 103 Terminal Box Rev A Manual 7 8 99 This product complies with the essential protection requirements of the EC EMC Directive 89 336 EC Davis Instruments Corp 1996...

Reviews: