TMP92CZ26A
92CZ26A-556
LCD Sub Area HOT Point Register (X-dir)
7 6 5 4 3 2 1 0
bit
Symbol SAH7 SAH6 SAH5 SAH4 SAH3 SAH2 SAH1 SAH0
Read/Write R/W R/W R/W R/W R/W R/W R/W R/W
After
reset
0 0 0 0 0 0 0 0
Function
LCD sub area HOT point (7-0)
7 6 5 4 3 2 1 0
bit
Symbol
SAH9
SAH8
Read/Write
R/W
R/W
After reset
0
0
Function
LCD sub area HOT point (9-8)
LCD Sub Area HOT Point Register (Y-dir)
7 6 5 4 3 2 1 0
bit
Symbol SAHY7 SAHY6 SAHY5
SAHY4 SAHY3
SAHY2 SAHY1 SAHY0
Read/Write
R/W R/W R/W R/W R/W R/W R/W R/W
After
reset
0 0 0 0 0 0 0 0
Function
LCD sub area HOT point (7-0)
7 6 5 4 3 2 1 0
bit
Symbol
SAHY8
Read/Write
R/W
After reset
0
Function
LCD sub
area HOT
point
(9-8)
Note: The HOT point should be set in units of the specified number of dots, which is determined by the display
color mode and display RAM access data bus width.
LCD Sub Area Display Segment Size Register
7 6 5 4 3 2 1 0
bit
Symbol SAS7 SAS6 SAS5 SAS4 SAS3 SAS2 SAS1 SAS0
Read/Write
R/W R/W R/W R/W R/W R/W R/W R/W
After
reset
0 0 0 0 0 0 0 0
Function
LCD sub area segment size (7-0)
7 6 5 4 3 2 1 0
bit
Symbol
SAS9
SAS8
Read/Write
R/W
R/W
After reset
0
0
Function
LCD sub area segment size (9-8)
Note: The segment size should be set in units of the specified number of dots, which is determined by the display
color mode and display RAM access data bus width.
LSAHX
(02A8H)
(02A9H)
LSASS
(02ACH)
(02ADH)
LSAHY
(02AAH)
(02ABH)