3.7 Memory Test
3 Tests and Diagnostics
TECRA M5 Maintenance Manual (960-542)
[CONFIDENTIAL]
3-15
3.7 Memory
Test
To execute the Memory Test, select
2
from the DIAGNOSTIC TEST MENU, press
Enter
and follow the directions on the screen. Move the highlight bar to the subtest you want to
execute and press
Enter
.
Subtest 01
Conventional memory
This subtest writes a constant data to conventional memory (0 to 640 KB),
then reads the new data and compares the result with the original data.
Subtest 02
Protected Mode
NOTE: The CONFIG.SYS file must be configured without expanded memory manager
programs such as EMM386.EXE, EMM386.SYS or QEMM386.SYS. Also, the
HIMEM.SYS must be deleted from the CONFIG.SYS file.
This subtest writes constant data and address data (from 1MB to maximum
MB), and reads the new data and compares the result with the original data.
Subtest 03
Protected Mode (cache off)
This subtest executes the same way as the subtest 02 with the cache off.
Subtest 04
Cache memory (on/off)
To test the cache memory, a pass-through write-read comparison of ‘5Ah’
data is run repeatedly to the test area (‘7000’: ‘Program’ size to ‘7000’:
‘7FFF’ (32 KB)) to check the hit-miss ratio (on/off status) for CPU cache
memory. One test takes 3 seconds.
Number of misses
<
Number of hits
→
OK
Number of misses
≥
Number of hits
→
Fail
Subtest 05
Stress
Data (from 1MB to the maximum MB) is written from the 16KB write buffer
to the 16KB read buffer and compared the data in the buffers. The read buffer
starts from 0001 and the comparison is continued with the following read
buffer addresses: 0001, 0003, 0005, 0007, 0009, 000b, 000d and 000f.
Summary of Contents for TECRA M5
Page 10: ...x CONFIDENTIAL TECRA M5 Maintenance Manual 960 542 ...
Page 11: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Page 12: ...1 Hardware Overview 1 ii CONFIDENTIAL TECRA M5 Maintenance Manual 960 542 ...
Page 48: ...1 Hardware Overview 1 13 AC Adapter 1 34 CONFIDENTIAL TECRA M5 Maintenance Manual 960 542 ...
Page 49: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures ...
Page 50: ...2 Troubleshooting Procedures 2 ii CONFIDENTIAL TECRA M5 Maintenance Manual 960 542 ...
Page 125: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Page 126: ...3 Tests and Diagnostics 3 ii CONFIDENTIAL TECRA M5 Maintenance Manual 960 542 3 ...
Page 130: ...3 Tests and Diagnostics 3 vi CONFIDENTIAL TECRA M5 Maintenance Manual 960 542 ...
Page 231: ...Chapter 4 Replacement Procedures CONFIDENTIAL ...
Page 232: ...4 Replacement Procedures 4 ii CONFIDENTIAL TECRA M5 Maintenance Manual 960 542 ...
Page 329: ... CONFIDENTIAL Appendices ...
Page 330: ...Appendices App ii CONFIDENTIAL TECRA M5 Maintenance Manual 960 542 ...
Page 350: ...Appendices Appendix B Board Layout B 8 CONFIDENTIAL TECRA M5 Maintenance Manual 960 542 ...
Page 380: ...Appendices Appendix C Pin Assignments C 30 CONFIDENTIAL TECRA M5 Maintenance Manual 960 542 ...
Page 390: ...Appendices Appendix E Key Layout E 2 CONFIDENTIAL TECRA M5 Maintenance Manual 960 542 ...
Page 392: ...Appendices Appendix F Wiring diagrams F 2 CONFIDENTIAL TECRA M5 Maintenance Manual 960 542 ...
Page 398: ...Appendices Appendix I Reliability I 2 CONFIDENTIAL TECRA M5 Maintenance Manual 960 542 ...