2.3 Power Supply Troubleshooting
2 Troubleshooting Procedures
Satellite A50S/TECRA A3X Maintenance Manual (960-534) [CONFIDENTIAL]
2-9
DC power supply (AC adapter)
Error code
Meaning
10h
AC Adapter output voltage is over 16.5V.
11h
Common Dock output voltage is over 16.5V.
12h
Current from the DC power supply is over 7.00A.
13h
Current from the DC power supply is over 0.5A when there is no load.
14h
Abnormal current has been sensed.
Main Battery
Error code
Meaning
22h
Main battery discharge current is over 0.5A when there is no load.
23h
Main battery charge current is over 3.9A when AC adapter is not
connected.
24h
Abnormal current has been sensed.
25h
Main battery charge current is over 0.3A.
Second Battery
Error code
Meaning
32h
Second battery discharge current is over 0.5A when there is no load.
33h
Second battery charge current is over 3.9A. when AC adapter is not
connected.
34h
Abnormal current has been sensed.
35h
Second battery charge current is over 0.3A.
S3V output (P60)
Error code
Meaning
40h
S3V voltage is 3.47V or less when the computer is powered on/off.
45h
S3V voltage is 3.14V or less when the computer is powered on.
46h
S3V voltage is 3.14V or less when the computer is booting up.(CV
support)
Summary of Contents for Tecra A3X
Page 10: ...x CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 ...
Page 11: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Page 16: ...1 Hardware Overview 1 vi CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 ...
Page 51: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures ...
Page 105: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Page 110: ...3 Tests and Diagnostics 3 vi CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 ...
Page 217: ... CONFIDENTIAL Chapter 4 Replacement Procedures ...
Page 337: ... CONFIDENTIAL Appendices ...
Page 338: ...Appendices App ii CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 ...