3.2 Executing the Diagnostic Test
3 Tests and Diagnostics
Select the option you want to execute and press
Enter
. When you select
1- SYSTEM
TEST
, the following message will appear:
SYSTEM TEST NAME XXXXXX
xxxxxxx DIAGNOSTIC TEST VX.XX
[Ctrl]+[Break] ; test end
[Ctrl]+[C] ; key stop
SUB-TEST : XX
PASS COUNT : XXXXX
ERROR COUNT: XXXXX
WRITE DATA : XX
READ DATA : XX
ADDRESS : XXXXXX
STATUS : XXX
SUB-TEST MENU :
01 - ROM checksum
02 – Fan ON/OFF
03 - Geyserville
04 - Quick charge
05 - DMI read
99 - Exit to DIAGNOSTIC TEST MENU
NOTE: The menu displayed by your computer may be slightly different from the one
shown above.
Select the desired subtest number from the subtest menu and press
Enter
. The following
message will appear:
TEST LOOP : YES (or NO)
ERROR STOP : YES (or NO)
Use the right and left arrow keys to move the cursor to the desired option.
Selecting
YES
of TEST LOOP
increases the pass counter by one, each time the test cycle
ends and restarts the test cycle.
Selecting
NO
returns the process to the subtest menu after the test is complete.
3-6 [CONFIDENTIAL]
Satellite A50S/TECRA A3X Maintenance Manual (960-534)
Summary of Contents for Tecra A3X
Page 10: ...x CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 ...
Page 11: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Page 16: ...1 Hardware Overview 1 vi CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 ...
Page 51: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures ...
Page 105: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Page 110: ...3 Tests and Diagnostics 3 vi CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 ...
Page 217: ... CONFIDENTIAL Chapter 4 Replacement Procedures ...
Page 337: ... CONFIDENTIAL Appendices ...
Page 338: ...Appendices App ii CONFIDENTIAL Satellite A50S TECRA A3X Maintenance Manual 960 534 ...