4.20 LCD Unit/FL Inverter
4 Replacement Procedures
4.20 LCD Unit/FL Inverter
Removing the LCD unit/FL inverter
The following describes the procedure for removing the LCD unit and FL inverter (See
Figure 4-40 to 4-42).
1.
Peel off two
mask seals
from the front of the
display mask
and remove the following
screws
.
•
M2.5x6B
THIN BIND screw
x2
2.
Insert your fingers between the display mask and the
LCD
and remove the display
mask after unlatching the display mask.
Mask Seal
M2.5
×
6B THIN BIND
Display Mask
Figure 4-40 Removing Display Mask