Plasma display adapter=VGA compatible
When the Plasma display adaptor option is set to VGA compatible,
internal display controller is configured as a VGA compatible
plasma/CRT controller. In this case the remaining setup options
are:
Display device
Plasma display mode
Plasma gray scale
Display device: This option selects between using the CRT only (CRT
mode), and using both the CRT and the plasma display simultaneously
(dual display mode). In either case if a CRT is connected to the
T5200, the display mode of the plasma display is set to either color
or monochrome, according to the type of the CRT (color or
monochrome). In the dual display mode, the display mode of the
plasma display agrees with the mode of the CRT. In this case, the
border section of the CRT is not displayed on the plasma display.
-Plasma: Specifies the dual display
mode.this is the default
setting.
-CRT: Specifies the CRT mode.
Plasma Display mode: If there isn't a CRT attached to the T5200,
this option selects whether the plasma display uses monochrome mode
or color mode. If there is a CRT attached to the T5200, the display
mode of the plasma display is determined by the type of the CRT
(either monochrome or color), and the setting for this option has
no effect.
-Color: Displays in color mode.256 colors of color data are
converted to 16 intensity levels of gray (orange) for the plasma
display. This is the default setting.
-Monochrome: Displays in the monochrome mode.64 intensity levels of
gray are converted to 16 intensity levels of gray (orange) for the
plasma display.
<fig id=MMS\5200\52003_50.TIF>Page 3-50</fig>
-Plasma gray scale: This specifies the relationship between the
brightness levels for characters displayed in normal and intense
display modes. A setting of "Bright" indicates that the maximum
brightness level (gray scale level 15) will be used to display
characters, while a setting of "Semi-bright" indicates that a
slightly lower brightness level (gray scale level 11) will be used.
Normal: Semi-bright Intense: Bright (this is the default setting.)
Normal: Bright Intense: Semi-bright
Plasma display adapter = CGA compatible
When the Plasma display adapter option is set to CGA compatible,
the internal display controller is configured as a CGA compatible
plasma controller. In this case the remaining setup options are:
Plasma gray scale mode
Plasma font style