³ 91H ³DMA channel 1 error
³halt ³
³ 92H ³DMA page register error
³halt ³
³ 93H ³Memory refresh error
³halt ³
³ 94H ³1st 64KB memory error
³halt ³
³ 96H ³Error interrupt controller 1
³halt ³
³ 97H ³Error interrupt controller 2
³Continue³
³ 9BH ³VRAM error
³halt ³
³ 9FH ³Memory verify error at X:X ³
³
³ ³found X expanded X
³Continue³
³ ³Memory parity error at X:X:X ³
³
³ ³found X expected X
³Continue³
³ A0H ³Error interrupt and stuck NMI
³Continue³
³ A1H ³Error interrupts and stuck NMI
³Continue³
³ A2H ³Error interrupts and stuck NMI
³Continue³
³ A3H ³Error protect mode...
³Continue³
³ A4H ³Error sizing expansion memory
³Continue³
³ ASH ³Memory verify error at X:X:X ³
³
³ ³found X expected X
³Continue³
³ ³Memory parity error at X:X:X ³
³
³ ³found X expected
³Continue³
³ A6H ³Error processor exceptional interrupts...
³Continue³
³ A9H ³Refresh timing error
³Continue³
³ AEH ³Error encountered initializing ³
³
³ ³hard drive
³Continue³
³ CEH ³Cache memory address error
³halt ³
³ D4H ³First 64KB memory error
³halt ³
³ EFH ³LIM page register error
³Continue³
ÀÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÙ
<fig id=MMS\5200\52002_15.TIF>Page 2-15</fig>
PROCEDURE 3
Test Program Execution
1. Execute the following tests on the Diagnostic Test Menu. (Refer to
part 3 Test and Diagnostics.)
1. System test
2. Memory test
3. Keyboard test
4. Display test
5. Floppy disk test
6. Printer test
7. ASYNC test
8. Hard disk test
9. Real timer test
2. If an error is detected during the system test, ASYNC (SERIAL B)
test, or real timer test, go to PROCEDURE 4.
3. If an error is detected during the memory test, go to PROCEDURE 5.
4. If an error is detected during the ASYNC test (SERIAL A) or
printer test, go to PROCEDURE 6.
5. If an error is detected during the floppy disk test, go to FDD
problem isolation procedures in section 2.5.
6. If an error is detected during the hard disk test, go to HDD