T200/T200CS
2-11
Procedure 1
Message Check
When power is turned on while the space bar is held down, the system performs the Initial
Reliability Test (IRT) resident in BIOS ROM. IRT tests and initializes each IC on the system
board.
❑
If an error message is shown on the display, perform Check 1.
❑
If there is no error message, go to Procedure 2.
❑
If the test program is properly loaded, go to Procedure 3.
Check 1
If one of the following error messages is displayed on the screen, tap the display or
press the
F1
key as instructed. These errors occur when the system configuration
preserved in RTC memory (CMOS-type memory) is not the same as the actual
configuration or when data is lost.
Tapping the display or pressing the
F1
key as instructed causes the SETUP menu
to appear. If error message (b) appears often when power is turned on, replace
the RTC battery. If any other error message is displayed, perform Check 2.
(a)
*** Error in CMOS. Bad HDD type ***
Check system. Then tap any point on the screen
with the stylus or press [F1] key.
(b)
*** Error in CMOS. Bad battery ***
Check system. Then tap any point on the screen
with the stylus or press [F1] key.
(c)
*** Error in CMOS. Bad check sum ***
Check system. Then tap any point on the screen
with the stylus or press [F1] key.
(d)
*** Error in CMOS. Bad memory configuration ***
Check system. Then tap any point on the screen
with the stylus or press [F1] key.
(e)
*** Error in CMOS. Bad time function ***
Check system. Then tap any point on the screen
with the stylus or press [F1] key.
Check 2
If the following error message is displayed, tap the display or press any key as the
message instructs.
WARNING: RESUME FAILURE.
TAP ANY POINT ON SCREEN WITH STYLUS PEN OR PRESS
ANY KEY TO CONTINUE.
The error message appears when data stored in RAM under the resume function is
lost because the battery is discharged or the system board is damaged. Go to
Procedure 2.
If any other message appears, perform Check 3.
Summary of Contents for T200
Page 23: ...T200 T200CS 2 3 Figure 2 1 Troubleshooting Flowchart 1 2 ...
Page 24: ...2 4 T200 T200CS Figure 2 1 Troubleshooting Flowchart 2 2 ...
Page 82: ...3 32 T200 T200CS ...
Page 90: ...3 40 T200 T200CS Head XX Sector XX Model name ...
Page 154: ...B 2 T200 T200CS Figure B 2 Upper System Board FOGSD2 Back ...
Page 156: ...B 4 T200 T200CS B 2 Lower System Board FOGSU2 Figure B 3 Lower System Board FOGSU2 Front ...
Page 157: ...T200 T200CS B 5 Figure B 4 Lower System Board FOGSU2 Back ...
Page 170: ...T200 T200CS D 1 Appendix D USA Display Codes Table D 1 USA Display Codes ...