Installation
Step 8: Connect Stratagy Admin PC to Stratagy IVP8
16
Stratagy IVP8 Installation Guide 01/02
Step 8: Connect Stratagy Admin PC to
Stratagy IVP8
Communication between the Stratagy Admin PC and the Stratagy IVP8 is accomplished by one of
two methods: local or remote.
Stratagy IVP8 uses the serial Port 2 by default to communicate with the Stratagy Admin PC (see
Figure 1
). This setting can be changed using the admin_port parameter in the Stratagy System
Configuration file (see
Table 3
on
page 25
for detailed information).
Local Connection
➤
Using a null-modem cable, connect the Stratagy Admin PC to the Stratagy IVP8. A
prefabricated cable (SG-ADMCBL), designed expressly for Stratagy Admin communication
with the Stratagy IVP8, Stratagy DK and Stratagy Flash is available from Toshiba.
Note
If you wish to purchase individual cabling/connectors/adapters in lieu of purchasing the
Toshiba Stratagy Admin cable, we have provided the wiring diagrams (see
Figures 3
and
4
).
Figure 3
RS-232 DB9 to DB9 Cabling
1
4
2
3
5
6
7
8
6
3
2
5
1
4
8
7
9-pin
female
9-pin
female
Figure 4
RS-232 DB25 to DB9 Cabling
2
3
4
5
6
7
8
20
2
3
8
7
1
4
5
6
25-pin
female
9-pin
female
Summary of Contents for Stratagy IVP8
Page 1: ...Installation Guide Stratagy IVP8 ...
Page 59: ......