2 Troubleshooting Procedures
Satellite A660/A665 Series Maintenance Manual
18
Procedure 1: Diagnostic check
Procedure 2: Connector and replacement check
Procedure 1
Diagnostic check
Run the
test and Diagnostics
Program, which will automatically execute the Keyboard Test.
Refer to Chapter 3,
Tests and Diagnostics
for more information on how to run the program.
If an error is located, go to Procedure 2. If an error does not occur, the keyboard is
functioning ok.
Procedure 2
Connector and replacement check
The keyboard and/or system board may be disconnected or damaged. Disassemble the
computer following the steps described in Chapter 4,
Replacement Procedures
and perform
the following checks.
Check 1
Make sure the keyboard cable is firmly connected to the system board.
If the connection is loose, reconnect firmly and repeat Procedure 1. If there is still
an error, go to Check 2.
Check 2
The keyboard may be damaged. Replace it with a new one following the
instructions in Chapter 4.
If the problem still exists, perform Check 3.
Check 3
The system board may be damaged. Replace it with a new one following the
instructions in Chapter 4.
Summary of Contents for Satellite P755 Series
Page 22: ...Chapter 2 Troubleshooting Procedures ...
Page 23: ......
Page 87: ...2Troubleshooting Procedures Satellite A660 A665 Series Maintenance Manual 64 ...
Page 99: ...Chapter 3 Tests and Diagnostics ...
Page 112: ...3 Tests and Diagnostics Satellite A660 A665 Series Maintenance Manual 13 ...
Page 136: ...3 Tests and Diagnostics Satellite A660 A665 Series Maintenance Manual 37 ...
Page 152: ...Chapter 4 Replacement Procedures ...
Page 159: ......