2 Troubleshooting Procedures
Satellite M300 and Satellite Pro M300 Maintenance Manual (960-Q08)
29
Procedure 4
Diagnostic Test Program Execution Check
The HDD test program is stored in the Diagnostics Disk. Perform all of the HDD tests in the
Hard Disk Drive Test. Refer to Chapter 3,
Tests and Diagnostics,
for more information about
the HDD test program.
If an error is detected during the HDD test, an error code and status will be displayed. The
error codes and statuses are described in Table 2-8. If an error code is not displayed but the
problem still occurs, go to Procedure 5.
Table 2-8 2.5” Hard disk drive error code and status
Code Status
05
HDD - HDC NOT RESET ERROR
07
HDD - DRIVE NOT INITIALIZE
09
HDD - DMA BOUNDARY ERROR
0B
HDD - BAD TRACK ERROR
BB
HDD - UNDEFINED ERROR
08
HDD - OVERRUN ERROR (DRQ ON)
01
HDD - BAD COMMAND ERROR
02
HDD - ADDRESS MARK NOT FOUND
04
HDD - RECORD NOT FOUND ERROR
10
HDD - ECC ERROR
20
HDD - HDC ERROR
40
HDD - SEEK ERROR
80
HDD - TIME OUT ERROR
11
HDD - ECC RECOVER ENABLE
AA
HDD - DRIVE NOT READY
CC
HDD - WRITE FAULT
E0
HDD - STATUS ERROR
0A
HDD - BAD SECTOR
EE
HDD - ACCESS TIME ERROR
DA
HDD - NO HDD
12
HDD - DMA CRC ERROR