Parameter List (cont'd)
Adjustable range
Display
Function
10 ~ 100
10 ~ 199, 200 (OFF)
0: No, 1: Yes
0: Coast to stop
1: Stopping after deceleration
2: Stopping by emergency DC braking
0.0 ~ 20.0
0: Not activated
1: Activated (first running only at start up
after power on)
2: Activated (running only at start up)
Extended Parameters (Protection Group No. 06)
F600
F60I
F602
F603
F604
F605
Default
value
Motor overload protection level (%)
Stall protection level (%)
Fault trip saving
Emergency stop selection
Emergency DC inject time (s)
Open phase detection parameter
100
150
0
0
10
0
Adjustable range
Display
Function
0: Enable (except
FMod
and
CMod
in running)
1: Disable
2: Enable
0: Not changed
1: Change % into A, V
2:
F702
enable
3: Convert % into A, V,
F702
enable
0.01 ~ 200.0
Extended Parameters (Panel Group No. 07)
F700
F70I
F702
Default
value
Parameter setting disable selection
Unit selection
Frequency units multiplication factor
0
0
1.00
Adjustable range
Display
Function
0 : 1200bps
1 : 2400bps
2 : 4800bps
3 : 9600bps
0 : NONE
1 : EVEN
2 : ODD
0 ~ 63
0 (OFF), 1 ~ 100
Extended Parameters (Communication Group No. 08)
Default
value
Communication speed
Parity
Inverter number
Communication error trip time (s)
3
1
0
0
F800
F80I
F802
F803