background image

CAUTION

• Before using the remote controller (RBC-AMT31E), please read this Owner’s Manual.
• For installation except operation of the remote controller, refer to the Installation Manual attached to the air

conditioner unit.

• To use this remote controller safely and correctly, read this Instruction Manual thoroughly before use for

full understanding.

• After you read this manual, be sure to keep it so that one who uses the remote controller can read this

manual anytime.  If another person uses the remote controller, necessarily hand the Manual to him or her.

ADOPTION OF NEW REFRIGERANT

This Air Conditioner is a new type which adopts
a new refrigerant HFC (R410A) instead of the
conventional refrigerant R22 in order to prevent
destruction of the ozone layer.

PRUDENCE

• Avant d’utiliser la télécommande (RBC-AMT31E), veuillez lire ce Mode d’emploi.
• Consultez le Manuel d’installation du climatiseur uniquement pour installer la télécommande, pas pour la faire fonctionner.
• Pour utiliser cette télécommande de façon correcte et sûre, lisez attentivement ce Mode d’emploi en entier.
• Lorsque vous avez fini de lire ce Mode d’emploi, rangez-le soigneusement pour pouvoir le consulter par la suite.

Si une autre personne doit utiliser la télécommande, remettez-lui ce Mode d’emploi.

VORSICHT

• Lesen Sie dieses Benutzerhandbuch, bevor Sie die Fernbedienung (RBC-AMT31E) benutzen.
• Einzelheiten zur Installation der Fernbedienung finden Sie in dem dem Klimagerät beiliegenden Installationshandbuch.
• Lesen Sie das Handbuch sorgfältig, so dass Sie den Inhalt verstehen, um die Fernbedienung sicher und korrekt zu bedienen.
• Bewahren Sie das Handbuch nach dem Lesen so auf, dass jeder, der die Fernbedienung benutzen will, Zugriff auf das Handbuch hat.

Will eine andere Person die Fernbedienung benutzen, händigen Sie ihr das Handbuch aus.

AVVERTENZA

• Prima di usare il telecomando (RBC-AMT31E), raccomandiamo la lettura di questo manuale d’istruzioni destinato al proprietario.
• Solo per l’installazione del telecomando, non per il funzionamento, fare riferimento al manuale di installazione fornito con il condizionatore d’aria.
• Per utilizzare il telecomando correttamente e in condizioni di sicurezza, leggere completamente questo Manuale d’istruzioni.
• Dopo aver letto questo manuale, conservarlo a portata di mano di altri che debbano poi usare il telecomando.

Se un’altra persona deve usare il telecomando, raccomandare la lettura del manuale.

PRECAUCIÓN

• Lea este Manual del propietario antes de utilizar el mando a distancia (RBC-AMT31E).
• Para conocer más detalles sólo acerca de la instalación del mando a distancia, consulte el Manual de instalación que se adjunta con el aparato de aire

acondicionado.

• Para utilizar este mando a distancia de manera correcta y segura, lea con atención este Manual de instrucciones antes de utilizarlo para asegurarse de

que entiende totalmente su funcionamiento.

• Después de leer este manual, asegúrese de guardarlo, de modo que cualquier persona que utilice el mando a distancia pueda leerlo en cualquier

momento.  Si otra persona utiliza el mando a distancia, entréguele este Manual.

CUIDADO

• Antes de utilizar o controlador remoto (RBC-AMT31E), leia o presente Manual do Proprietário.
• Para pormenores acerca da instalação, excluindo o funcionamento, do controlador remoto, consulte o Manual de Instalação fornecido com o aparelho de

ar condicionado.

• Para utilizar este controlador remoto em segurança e correctamente, leia atentamente o presente Manual de Instruções antes da sua utilização para um

entendimento exaustivo.

• Depois da leitura do presente manual, guarde-o para que quem utilizar o controlador remoto o possa ler em qualquer altura.

Se outra pessoa utilizar o controlador remoto, faculte-lhe o Manual.

ÐÑÏÓÏ×Ç

• Ðñéí ÷ñçóéìïðïéÞóåôå ôï ôçëå÷åéñéóôÞñéï (RBC-AMT31E), ðáñáêáëïýìå äéáâÜóôå áõôü ôï Åã÷åéñßäéï ×ñÞóçò.

• Ãéá ôçí åãêáôÜóôáóç, åêôüò áðü ôç ëåéôïõñãßá ôïõ ôçëå÷åéñéóôçñßïõ, äåßôå ôï Åã÷åéñßäéï ÅãêáôÜóôáóçò ðïõ åßíáé ðñïóáñôçìÝíï óôç ìïíÜäá êëéìáôéóìïý.

• Ãéá íá ÷ñçóéìïðïéÞóåôå áõôü ôï ôçëå÷åéñéóôÞñéï ìå áóöáëÞ ôñüðï êáé óùóôÜ, äéáâÜóôå ðñïóåêôéêÜ áõôü ôï Åã÷åéñßäéï ÅãêáôÜóôáóçò þóôå íá

êáôáíïÞóåôå êáëÜ ôç ëåéôïõñãßá ôïõ.

• Áöïý äéáâÜóåôå áõôü ôï åã÷åéñßäéï, öõëÜîôå ôï, þóôå íá ìðïñåß áíÜ ðÜóá óôéãìÞ íá ôï äéáâÜóåé êÜðïéïò ðïõ èá ÷ñçóéìïðïéÞóåé ôï ôçëå÷åéñéóôÞñéï.

Áí Ýíá Üëëï Üôïìï ÷ñçóéìïðïéÞóåé ôï ôçëå÷åéñéóôÞñéï, äþóôå ôïõ áõôü ôï Åã÷åéñßäéï.

LET OP

• Lees voordat u de afstandsbediening (RBC-AMT31E) gaat gebruiken eerst deze gebruiksaanwijzing.
• Meer informatie over de installatie (dus niet over de werking) van de afstandsbediening vindt u in de installatiehandleiding bij de

airconditionerunit.

• Lees voor een veilig en correct gebruik van deze afstandsbediening deze handleiding aandachtig door.
• Bewaar deze handleiding, zodat u deze in de toekomst zonodig nogmaals kunt nalezen.

Overhandig de handleiding, als iemand anders de afstandsbediening gebruikt, aan deze persoon.

 (RBC-AMT31E) 

Summary of Contents for RBC-AMT31-E

Page 1: ... Type MMD AP0181H AP0241H AP0271H AP0361H AP0481H AP0721H AP0961H Under Ceiling Type MMC AP0151H AP0181H AP0241H AP0271H AP0361H AP0481H High Wall Type MMK AP0071H AP0072H AP0091H AP0092H AP0121H AP0122H AP0151H AP0181H AP0241H Floor Standing Cabinet Type MML AP0071H AP0091H AP0121H AP0151H AP0181H AP0241H Floor Standing Concealed Type MML AP0071BH AP0091BH AP0121BH AP0151BH AP0181BH AP0241BH Floo...

Page 2: ...ona deve usare il telecomando raccomandare la lettura del manuale PRECAUCIÓN Lea este Manual del propietario antes de utilizar el mando a distancia RBC AMT31E Para conocer más detalles sólo acerca de la instalación del mando a distancia consulte el Manual de instalación que se adjunta con el aparato de aire acondicionado Para utilizar este mando a distancia de manera correcta y segura lea con aten...

Page 3: ...NTO CONTIMER 38 REGOLAZIONE DELLA DIREZIONE DELL ARIA 39 MANUTENZIONE 43 RISOLUZIONE DEI PROBLEMI 44 PRECAUCIONES DE SEGURIDAD 45 DESCRIPCIÓN DE LOS BOTONES DEL CONTROL REMOTO 46 UTILIZACIÓN CORRECTA 48 FUNCIONAMIENTO DELTEMPORIZADOR 49 AJUSTE DE LA DIRECCIÓN DEL AIRE 50 MANTENIMIENTO 54 RESOLUCIÓN DE PROBLEMAS 55 PRECAUÇÃO DE SEGURANÇA 56 NOME DAS PEÇAS DO CONTROLADOR REMOTO 57 UTILIZAÇÃO CORRECT...

Page 4: ...and so on A person qualified for the electric work should deal with the electric construction conforming to the regulations of the local electric company and the Installation Manual Be sure to use the exclusive circuit If there is capacity shortage of the power supply circuit or incomplete installation a fire or an electric shock is caused For wiring use the specified wires and connect them secure...

Page 5: ...on is pushed 15 Air volume select display The selected air volume mode is displayed AUTO HIGH MED LOW In the Concealed Duct High Static Pressure type models HIGH only is displayed for the air speed 16 Mode select control display Displayed when pushing Operation mode select button while the operation mode is fixed to heating or cooling by the system manager of the air conditioner 17 Central control...

Page 6: ...p the auto swing and angle of the flap This function is not provided to Concealed Duct Standard Type High Static Pressure Type Floor standing Cabinet Type Floor Standing Concealed Type or Slim Duct Type 7 Operation lamp Lamp is lit during the operation Lamp is off when stopped Although it flashes when operating the protec tion device or abnormal time 8 ON OFF button When the button is pushed the o...

Page 7: ...Pressure Type but air speed HIGH only is displayed 4 Determine the set up temperature by pushing the TEMP or TEMP button Stop Push ON OFF button The operation lamp goes off and the operation stops CORRECT USAGE When you use the air conditioner for the first time or when you change the SET DATA value follow the proce dure below From the next time the operation displayed on the remote controller wil...

Page 8: ...24 hr time increases in the unit of 1 hr The maximum setup time is 168 hr On the remote controller the setup time is displayed with numerals for 0 5 hr to 23 5 hr 1 and time over 24 hr 2 is displayed by No of days and time Every pushing button the setup time is decreased in the unit of 0 5 hr 30 minutes From 0 5 hr to 23 5 hr or in the unit of 1 hr From 24 hr to 168 hr Display example of remote co...

Page 9: ...fall down REQUIREMENT If heating operation is performed with horizontal discharge unevenness of temperature may increase in the room 4 way Air Discharge Cassette Under Ceiling Type While the air conditioner stops the discharge flap automatically directs downward While the air conditioner is in ready status for heating the discharge flap directs upward The swinging operation starts after heating re...

Page 10: ...ap The air outlet flap can be stopped at the desired position After then the air direction can be again set up from the uppermost position by pushing SWING FIX button While the air outlet flap is set downward in cooling drying operation it does not stop If stopping the air outlet flap which directs downward during swinging it stops after moving to the 3rd position from the top position 4 UNIT To s...

Page 11: ...ote controller controls the multiple indoor units each indoor unit can be selected and its air direction can be set up 1 2 3 ON OFF FAN TEMP SWING FIX TIME MODE VENT UNIT SET CL FILTER RESET TEST TIMER SET Unit No 1 1 No display Unit No 1 2 Unit No 1 4 Unit No 1 3 2 Push SWING FIX button again during swinging of the air outlet flapp The air outlet flap can be stopped at the desired position 3 UNIT...

Page 12: ...horizontal flap with downward set point so that the hot air blows at the foot REQUIREMENT If cooling operation is performed with downward air outlet dew may fall on surface of the cabinet or the horizontal flap resulted in dripping If heating operation is performed with horizontal air outlet unevenness of temperature may increase in the room Do not move the horizontal flap directly with hands othe...

Page 13: ...ng function 1 2 In this case do not use the swing function FILTER display Notifies the time to clean the air filter FILTER reset Push the FILTER switch after cleaning FILTER display disappears ON OFF FAN TEMP SWING FIX TIME MODE VENT UNIT SET CL FILTER RESET TEST TIMER SET CODENo UNIT No TEST SETTING DATA SET R C No H MAINTENANCE Cleaning of air filter When FILTER is displayed on the remote contro...

Page 14: ...T TEST TIMER SET Procedure 1 2 3 Description When pushing SET and TEST buttons at the same time for 4 seconds or more the following display appears If Service check is displayed the mode enters in the trouble history mode 01 Order of trouble history is displayed in CODE No window Check code is displayed in CHECK window Indoor unit address in which an error occurred is displayed in UNIT No Every pu...

Page 15: ...EH99923001 ...