background image

4

1

Push 

ON / OFF

 button.

The operation lamp goes on, and the operation starts.

2

Select an operation mode with the 

MODE

 button.

One push of the button, and the display
changes in the order shown on the right.

• “DRY   mode” function is not provided to

Concealed Duct High Static Pressure Type.

3

Select air volume with 

FAN

 button.

One push of the button, and the display changes in the order shown on the right.

• When air volume is “AUTO 

”, air volume differs according to the room temperature.

• In DRY   mode, “AUTO 

” is displayed and the air volume is LOW.

• In heating operation, if the room temperature is not heated sufficiently with volume “LOW 

” operation,

select “MED. 

” or “HIGH 

” operation.

• The temperature which the temperature sensor detects is one near the air inlet of the indoor unit.

Therefore it slightly differs from the room temperature according to the installation status. The setup
value is a criterion of the room temperature. (Automatic air speed cannot be selected in FAN mode.)

• Air volume of function is not provided to “Concealed Duct High Static Pressure Type” but air speed

“HIGH 

” only is displayed.

4

Determine the set up temperature by pushing the “TEMP. 

” or “TEMP. 

”  button.

Stop

Push 

ON / OFF

 button.

The operation lamp goes off, and the operation stops.

CORRECT USAGE

When you use the air conditioner for the first time or when you change the SET DATA value, follow the proce-
dure below. From the next time, the operation displayed on the remote controller will start by pushing the

ON / OFF

 button only.

Preparation

Turn on the main power switch and/or the leakage breaker.

• When the power supply is turned on, a partition line is displayed on the display part of the remote controller.

*

After the power supply is turned on, the remote controller does not accept an operation for approx. 1 minute,
but it is not a failure.

REQUIREMENT

• While using the air conditioner, operate it only with 

ON / OFF

 button without turning off the main power

switch and the leak breaker.

• Do not turn off the leak breaker while the air conditioner is used.

• Turn on the leak breaker 12 hours or more before start of operation after the air conditioner has stopped

for a long time.

4

ON / OFF

FAN

TEMP.

SWING/FIX

TIME

MODE

VENT

UNIT

SET

CL

FILTER
RESET TEST

TIMER SET

        LOW

         MED.

         HIGH

     AUTO

HEAT

DRY

COOL

FAN

AUTO

(Dehumidity)

Summary of Contents for RBC-AMT31-E

Page 1: ... Type MMD AP0181H AP0241H AP0271H AP0361H AP0481H AP0721H AP0961H Under Ceiling Type MMC AP0151H AP0181H AP0241H AP0271H AP0361H AP0481H High Wall Type MMK AP0071H AP0072H AP0091H AP0092H AP0121H AP0122H AP0151H AP0181H AP0241H Floor Standing Cabinet Type MML AP0071H AP0091H AP0121H AP0151H AP0181H AP0241H Floor Standing Concealed Type MML AP0071BH AP0091BH AP0121BH AP0151BH AP0181BH AP0241BH Floo...

Page 2: ...ona deve usare il telecomando raccomandare la lettura del manuale PRECAUCIÓN Lea este Manual del propietario antes de utilizar el mando a distancia RBC AMT31E Para conocer más detalles sólo acerca de la instalación del mando a distancia consulte el Manual de instalación que se adjunta con el aparato de aire acondicionado Para utilizar este mando a distancia de manera correcta y segura lea con aten...

Page 3: ...NTO CONTIMER 38 REGOLAZIONE DELLA DIREZIONE DELL ARIA 39 MANUTENZIONE 43 RISOLUZIONE DEI PROBLEMI 44 PRECAUCIONES DE SEGURIDAD 45 DESCRIPCIÓN DE LOS BOTONES DEL CONTROL REMOTO 46 UTILIZACIÓN CORRECTA 48 FUNCIONAMIENTO DELTEMPORIZADOR 49 AJUSTE DE LA DIRECCIÓN DEL AIRE 50 MANTENIMIENTO 54 RESOLUCIÓN DE PROBLEMAS 55 PRECAUÇÃO DE SEGURANÇA 56 NOME DAS PEÇAS DO CONTROLADOR REMOTO 57 UTILIZAÇÃO CORRECT...

Page 4: ...and so on A person qualified for the electric work should deal with the electric construction conforming to the regulations of the local electric company and the Installation Manual Be sure to use the exclusive circuit If there is capacity shortage of the power supply circuit or incomplete installation a fire or an electric shock is caused For wiring use the specified wires and connect them secure...

Page 5: ...on is pushed 15 Air volume select display The selected air volume mode is displayed AUTO HIGH MED LOW In the Concealed Duct High Static Pressure type models HIGH only is displayed for the air speed 16 Mode select control display Displayed when pushing Operation mode select button while the operation mode is fixed to heating or cooling by the system manager of the air conditioner 17 Central control...

Page 6: ...p the auto swing and angle of the flap This function is not provided to Concealed Duct Standard Type High Static Pressure Type Floor standing Cabinet Type Floor Standing Concealed Type or Slim Duct Type 7 Operation lamp Lamp is lit during the operation Lamp is off when stopped Although it flashes when operating the protec tion device or abnormal time 8 ON OFF button When the button is pushed the o...

Page 7: ...Pressure Type but air speed HIGH only is displayed 4 Determine the set up temperature by pushing the TEMP or TEMP button Stop Push ON OFF button The operation lamp goes off and the operation stops CORRECT USAGE When you use the air conditioner for the first time or when you change the SET DATA value follow the proce dure below From the next time the operation displayed on the remote controller wil...

Page 8: ...24 hr time increases in the unit of 1 hr The maximum setup time is 168 hr On the remote controller the setup time is displayed with numerals for 0 5 hr to 23 5 hr 1 and time over 24 hr 2 is displayed by No of days and time Every pushing button the setup time is decreased in the unit of 0 5 hr 30 minutes From 0 5 hr to 23 5 hr or in the unit of 1 hr From 24 hr to 168 hr Display example of remote co...

Page 9: ...fall down REQUIREMENT If heating operation is performed with horizontal discharge unevenness of temperature may increase in the room 4 way Air Discharge Cassette Under Ceiling Type While the air conditioner stops the discharge flap automatically directs downward While the air conditioner is in ready status for heating the discharge flap directs upward The swinging operation starts after heating re...

Page 10: ...ap The air outlet flap can be stopped at the desired position After then the air direction can be again set up from the uppermost position by pushing SWING FIX button While the air outlet flap is set downward in cooling drying operation it does not stop If stopping the air outlet flap which directs downward during swinging it stops after moving to the 3rd position from the top position 4 UNIT To s...

Page 11: ...ote controller controls the multiple indoor units each indoor unit can be selected and its air direction can be set up 1 2 3 ON OFF FAN TEMP SWING FIX TIME MODE VENT UNIT SET CL FILTER RESET TEST TIMER SET Unit No 1 1 No display Unit No 1 2 Unit No 1 4 Unit No 1 3 2 Push SWING FIX button again during swinging of the air outlet flapp The air outlet flap can be stopped at the desired position 3 UNIT...

Page 12: ...horizontal flap with downward set point so that the hot air blows at the foot REQUIREMENT If cooling operation is performed with downward air outlet dew may fall on surface of the cabinet or the horizontal flap resulted in dripping If heating operation is performed with horizontal air outlet unevenness of temperature may increase in the room Do not move the horizontal flap directly with hands othe...

Page 13: ...ng function 1 2 In this case do not use the swing function FILTER display Notifies the time to clean the air filter FILTER reset Push the FILTER switch after cleaning FILTER display disappears ON OFF FAN TEMP SWING FIX TIME MODE VENT UNIT SET CL FILTER RESET TEST TIMER SET CODENo UNIT No TEST SETTING DATA SET R C No H MAINTENANCE Cleaning of air filter When FILTER is displayed on the remote contro...

Page 14: ...T TEST TIMER SET Procedure 1 2 3 Description When pushing SET and TEST buttons at the same time for 4 seconds or more the following display appears If Service check is displayed the mode enters in the trouble history mode 01 Order of trouble history is displayed in CODE No window Check code is displayed in CHECK window Indoor unit address in which an error occurred is displayed in UNIT No Every pu...

Page 15: ...EH99923001 ...

Reviews: