background image

7

How to set up the air direction

Push 

SWING/FIX

 button.

1

Every pushing the button, the air direction changes.

In Heating operation

Set the air outlet flap downward.
If directing it upward, the hot air may not come to the foot.

In Cooling / Dry operation

Set the air outlet flap upward.
If directing it downward, the dew may fall on near the air discharge port or it drips.

How to start swinging

2

Push 

SWING/FIX

 button.

Set direction of the air outlet flap to the
lowest position and then push 

SWING/FIX

 button

again.
• [SWING 

 ] is displayed and the air direction

automatically changes upward/downward.

In case when one remote controller controls
the multiple indoor units, each indoor unit can
be selected and its air direction can be set up.

How to stop swinging

3

Push 

SWING/FIX

 button again during swinging of

the air outlet flap.
• The air outlet flap can be stopped at the

desired position. After then the air direction
can be again set up from the uppermost

position by pushing 

SWING/FIX

 button.

* While the air outlet flap is set downward in

cooling/drying operation, it does not stop.
If stopping the air outlet flap which directs
downward during swinging, it stops after
moving to the 3rd position from the top
position.

4

UNIT

• To set up the air direction individually, push

UNIT

 button to display each indoor unit No. in

a group control. Then set up the air direction to
a displayed indoor unit.

• If there is no display, all the indoor units can be

operated collectively.

• Every pushing 

UNIT

 button, the display

exchanges as shown in the figure.

Initial setup

Initial setup

In FAN operation

1, 2, 3

4

In all modes

Display when stopping the swing

Initial setup

Series of 
operation

Fan/Heat 
operation

Cool/Dry 
operation

ON / OFF

FAN

TEMP.

SWING/FIX

TIME

MODE

VENT

UNIT

SET

CL

FILTER
RESET TEST

TIMER SET

Unit No. 1-1

No display

Unit No. 1-2

Unit No. 1-4

Unit No. 1-3

Summary of Contents for RBC-AMT31-E

Page 1: ... Type MMD AP0181H AP0241H AP0271H AP0361H AP0481H AP0721H AP0961H Under Ceiling Type MMC AP0151H AP0181H AP0241H AP0271H AP0361H AP0481H High Wall Type MMK AP0071H AP0072H AP0091H AP0092H AP0121H AP0122H AP0151H AP0181H AP0241H Floor Standing Cabinet Type MML AP0071H AP0091H AP0121H AP0151H AP0181H AP0241H Floor Standing Concealed Type MML AP0071BH AP0091BH AP0121BH AP0151BH AP0181BH AP0241BH Floo...

Page 2: ...ona deve usare il telecomando raccomandare la lettura del manuale PRECAUCIÓN Lea este Manual del propietario antes de utilizar el mando a distancia RBC AMT31E Para conocer más detalles sólo acerca de la instalación del mando a distancia consulte el Manual de instalación que se adjunta con el aparato de aire acondicionado Para utilizar este mando a distancia de manera correcta y segura lea con aten...

Page 3: ...NTO CONTIMER 38 REGOLAZIONE DELLA DIREZIONE DELL ARIA 39 MANUTENZIONE 43 RISOLUZIONE DEI PROBLEMI 44 PRECAUCIONES DE SEGURIDAD 45 DESCRIPCIÓN DE LOS BOTONES DEL CONTROL REMOTO 46 UTILIZACIÓN CORRECTA 48 FUNCIONAMIENTO DELTEMPORIZADOR 49 AJUSTE DE LA DIRECCIÓN DEL AIRE 50 MANTENIMIENTO 54 RESOLUCIÓN DE PROBLEMAS 55 PRECAUÇÃO DE SEGURANÇA 56 NOME DAS PEÇAS DO CONTROLADOR REMOTO 57 UTILIZAÇÃO CORRECT...

Page 4: ...and so on A person qualified for the electric work should deal with the electric construction conforming to the regulations of the local electric company and the Installation Manual Be sure to use the exclusive circuit If there is capacity shortage of the power supply circuit or incomplete installation a fire or an electric shock is caused For wiring use the specified wires and connect them secure...

Page 5: ...on is pushed 15 Air volume select display The selected air volume mode is displayed AUTO HIGH MED LOW In the Concealed Duct High Static Pressure type models HIGH only is displayed for the air speed 16 Mode select control display Displayed when pushing Operation mode select button while the operation mode is fixed to heating or cooling by the system manager of the air conditioner 17 Central control...

Page 6: ...p the auto swing and angle of the flap This function is not provided to Concealed Duct Standard Type High Static Pressure Type Floor standing Cabinet Type Floor Standing Concealed Type or Slim Duct Type 7 Operation lamp Lamp is lit during the operation Lamp is off when stopped Although it flashes when operating the protec tion device or abnormal time 8 ON OFF button When the button is pushed the o...

Page 7: ...Pressure Type but air speed HIGH only is displayed 4 Determine the set up temperature by pushing the TEMP or TEMP button Stop Push ON OFF button The operation lamp goes off and the operation stops CORRECT USAGE When you use the air conditioner for the first time or when you change the SET DATA value follow the proce dure below From the next time the operation displayed on the remote controller wil...

Page 8: ...24 hr time increases in the unit of 1 hr The maximum setup time is 168 hr On the remote controller the setup time is displayed with numerals for 0 5 hr to 23 5 hr 1 and time over 24 hr 2 is displayed by No of days and time Every pushing button the setup time is decreased in the unit of 0 5 hr 30 minutes From 0 5 hr to 23 5 hr or in the unit of 1 hr From 24 hr to 168 hr Display example of remote co...

Page 9: ...fall down REQUIREMENT If heating operation is performed with horizontal discharge unevenness of temperature may increase in the room 4 way Air Discharge Cassette Under Ceiling Type While the air conditioner stops the discharge flap automatically directs downward While the air conditioner is in ready status for heating the discharge flap directs upward The swinging operation starts after heating re...

Page 10: ...ap The air outlet flap can be stopped at the desired position After then the air direction can be again set up from the uppermost position by pushing SWING FIX button While the air outlet flap is set downward in cooling drying operation it does not stop If stopping the air outlet flap which directs downward during swinging it stops after moving to the 3rd position from the top position 4 UNIT To s...

Page 11: ...ote controller controls the multiple indoor units each indoor unit can be selected and its air direction can be set up 1 2 3 ON OFF FAN TEMP SWING FIX TIME MODE VENT UNIT SET CL FILTER RESET TEST TIMER SET Unit No 1 1 No display Unit No 1 2 Unit No 1 4 Unit No 1 3 2 Push SWING FIX button again during swinging of the air outlet flapp The air outlet flap can be stopped at the desired position 3 UNIT...

Page 12: ...horizontal flap with downward set point so that the hot air blows at the foot REQUIREMENT If cooling operation is performed with downward air outlet dew may fall on surface of the cabinet or the horizontal flap resulted in dripping If heating operation is performed with horizontal air outlet unevenness of temperature may increase in the room Do not move the horizontal flap directly with hands othe...

Page 13: ...ng function 1 2 In this case do not use the swing function FILTER display Notifies the time to clean the air filter FILTER reset Push the FILTER switch after cleaning FILTER display disappears ON OFF FAN TEMP SWING FIX TIME MODE VENT UNIT SET CL FILTER RESET TEST TIMER SET CODENo UNIT No TEST SETTING DATA SET R C No H MAINTENANCE Cleaning of air filter When FILTER is displayed on the remote contro...

Page 14: ...T TEST TIMER SET Procedure 1 2 3 Description When pushing SET and TEST buttons at the same time for 4 seconds or more the following display appears If Service check is displayed the mode enters in the trouble history mode 01 Order of trouble history is displayed in CODE No window Check code is displayed in CHECK window Indoor unit address in which an error occurred is displayed in UNIT No Every pu...

Page 15: ...EH99923001 ...

Reviews: