– 31 –
NO.
11
Item
Louver
control
Overview of specifications
(1) During the first operation after power on, louver position is controlled
automatically according to operation mode (COOL/HEAT).
COOL/DRY
HEAT/FAN
(2) When louver position is controlled by remote controller, the unit’s
microcomputer memorizes the position for use in the next operation.
• The memorized louver position is cleared when power is turned off,
and returns to the state of (1) above.
(3) Louver position setting
• Louver position can be set within the range below.
COOL
45°C
HEAT
103°
• Louver position can be set collectively or individually in the group
twin or triple operation mode.
(Wireless remote controller allows individual setting only.)
(4) Swing setting
• Louver moves within the range below.
All operation modes
• Louver swing range can be set collectively or individually in the group
twin or triple operation mode. (Setting by wireless remote controller is
disabled when the main remote controller is used.)
(5) When air conditioner operation stops, louver closes automatically.
It keeps its position in the event of an alarm.
(6) Louver tilts upward automatically during preparation for heating.
(7) In the twin or triple operation mode selected by wireless remote
controller, swing setting interlocks with the header indoor unit. If this
setting is transmitted from a follower indoor unit, operation does not
change with a reception sound “pi, pi, pi” if operatio mode differs
between header unit and follower unit.
Remarks
Louver angle: 0°C
(full close)
Full ciose
0°
Alarm : A code number
(except F08 and
L31) appears on
the remote
controller and the
indoor unit stops.