– 33 –
NO.
16
Item
Maximum frequency
limit control
Overview of specifications
(1) This control is performed when AUTO mode is selected.
(2) COOL mode: When To is under 28°C, the control is as follows.
Remarks
(3) HEAT mode: When To is over 15°C, the control is as follows.
+4
+3
Tsc
Ta
(˚C)
Normal control
Maximum frequency is
limited to the rating of cooling.
Tsh
–3
–4
Ta
(˚C)
Normal control
Maximum frequency is
limited to the rating of heatong.
(1) When the fan operation has started, positioning of the stator and the
rotor are performed. (Moves slightly with tap sound)
(2) The motor operates according to the command from the indoor
controller.
Notes)
• When the fan rotates while the air conditioner stops due to entering of
outside air, etc, the air conditioner may operate while the fan motor
stops.
• When a fan lock is found, the air conditioner stops, and an error is
displayed.
(1) Turn on
SAVE
button on the wired remote controller.
(2) During operation of save operation,
lights on the wired remote
controller.
(3) During save operation, the current release control is performed with
the restriction ratio set in EEPROM on the outdoor unit.
(4) The restriction ratio can be set by keeping
SAVE
button pushed for
4 seconds or more on the remote controller.
(5) When validating the save operation, the next operation starts with
save operation valid because contents are held even when operation
stops, operation mode changes or power supply is reset.
(6) The restriction ratio can be set by changing the setup data of CODE
No. (DN) [C2] in the range of 50 to 100%
(every 1%, Setting at shipment: 75%).
17
18
DC motor
Save operation
(Wired remote
controller specific
operation)
Check code [P12}
Carry out setting
operation during
stop of the unit;
otherwise the unit
stops operation.
For the setup
operation, refer to
“How to set up
contents of save
operation” of
“
10. ON-SITE
SETTING AND
OTHERS
”.