– 41 –
F5
F4
47
42
F5
Tc
(˚C)
No.
5
Item
Air speed
selection
(Continued)
Outline of specifications
<HEAT>
Remarks
Value in the parentheses indicates one when thermostat of
the remote controller works.
Value without parentheses indicates one when thermostat
of the body works.
• If the air speed has been changed once, it is not
changed for 1 minute. However when the air speed is
exchanged, the air speed changes.
• When heating operation has started, the air speed
selects a upward slope, that is, the high position.
• If the temperature is just on the difference boundary, the
air speed does not change.
• Mode in the parentheses indicates one in automatic
heating operation.
• In Tc
≥
60°C, the air speed increases by 1 step.
<Operation of duct only>
Tc: Indoor heat exchanger
sensor temperature
Standard
COOL HEAT
UL
UL
L
L+
L
L+
M
M
M+
M+
H
H
High ceiling
COOL HEAT
UL
UL
L
L
L+
L+
M+,M M+,M
H
H
Tap
FD
FD
FB
FA
F9
F8
F7
F6
F5
F4
F3
F2
F1
SM560
SM800
Revolutions per
minute (rpm)
320
320
320
330
330
340
350
360
360
370
370
380
400
410
410
440
420
450
440
480
480
500
530
540
580
580
3) In heating operation, the mode changes to [UL] if
thermostat is turned off.
4) If Ta
≥
25°C when heating operation has started and
when defrost operation has been cleared, it operates
with HIGH (H) mode or (HH) for 1 minute from when Tc
has entered in E zone of cool air discharge preventive
control (Item 6).
5) In automatic cooling/heating operation, the revolution
frequency of [HH] is set larger than that in the standard
cooling/heating operation. However the revolution
frequency is restricted in the automatic heating opera-
tion as shown in the following figure.
–1.0
Ta (˚C)
E
D
C
B
A
(-0.5)
L(L)
L(H)
H(H)
H
HH
(HH)
(HH)
+1.0
(+0.5)
+2.0
(+1.0)
+3.0
(+1.5)
+4.0
(+2.0)
Tsh
(0)
[PRE-HEAT] display
Summary of Contents for RAV-SM560AT-E
Page 187: ......