background image

– 14 –

EN

EN

ID

 

8 °C OPERATION (For object pre-heating) 
(SDI series 4 and DI series 4 only)

The air conditioner can control the heating temperature to about 8 °C in the heating mode.

The 8 °C heating operation requires settings with the wired remote controller. Ask the installer or dealer 
for the settings according to the installation manual of the indoor unit.

Start

1

  Set the displayed temperature to 18 °C in the heating mode by pushing TEMP. 

 button.

2

  Set the displayed temperature to 8 °C by pushing TEMP. 

 button for at least four seconds.

Stop

1

  Set the displayed temperature to 18 °C by pushing TEMP. 

 button.

•  The air conditioner returns to the normal HEAT mode. Select a desired temperature and operation mode.

NOTE

•  The discharged air temperature is lower than that in the normal heating operation.
•  The room temperature may not be heated evenly depending on the remote controller installation location.
•  The room temperature may not reach 8 °C depending on the room size or the installation conditions.
•  Setting for fan speed is available during the 8 °C heating operation.

The 8 °C heating operation is cancelled in the following cases.
•  When operation is stopped with 

 button

•  When another operation mode is selected with 

 button

•  When temperature setting or operation mode is changed or operation is started / stopped by the wireless 

remote controller or the central control remote controller.

•  When this operation mode is used, observe proper operating hours and we recommend that you ask service 

staff for periodic maintenance of the air conditioner.

27-EN

28-EN

5-1. Correct usage

When the air conditioner is used for the first time or when the setting is changed, follow the steps below. Settings 
are saved in memory and are displayed anytime the unit is turned on by pushing the 

 button.

 

Preparation

•  When the circuit breaker is turned on, the partition 

lines are displayed on the remote controller.

*  

After the circuit breaker is turned on, the remote 
controller does not accept any commands for 
approx. 1 minute, this is not a failure.

REQUIREMENT

When the air conditioner is re-powered after it has not 
been used for a long period, turn on the circuit breaker 
at least 12 hours before starting the air conditioner.

SET

TIME

TIMER SET

TEST

FILTER

RESET

TEMP.

CL

FAN

SAVE

SWING/FIX

VENT

MODE

ON / OFF

UNIT  LOUVER

4

 

Start

1

 Push 

 button.

The operation lamp illuminates, and the operation 
starts.

2

  Select an operation mode with the “ 

 ” 

button.

One push of the button, and the display changes 
in the order shown below.

Auto

Heat

Dry

Cool

Fan

3

  Select fan speed with “ 

 ” button.

One push of the button, and the display changes 
in the order shown below.

     

Auto

High

Med.

Low

•  When fan is in “ 

 AUTO”, fan speed is 

adjusted based on difference between set point 
and room temperature.

•  In heating operation, if the room temperature 

is not heated suf

fi

 ciently with speed “   LOW” 

operation, select “ 

 MED.” or “ 

 HIGH” 

operation.

•  The temperature sensor detects the return air 

temperature at the indoor unit, which differs 
from the room temperature depending on the 
installation condition.
Set point is a target of room temperature.

 “Auto” is not selectable in the Fan mode.)

4

  Select the set point temperature by 

pushing the “TEMP. 

” or “TEMP. 

” 

buttons.

 

Stop

1

 Push 

 button.

The operation lamp goes off, and the operation 
stops.
In the COOL, DRY, or AUTO (cooling) mode, the 
fan runs for 10 minutes (or more) for dehydrating 
heat exchanger operation.

NOTE

Auto Changeover

•  During Auto Mode, the unit selects the operating 

mode (cooling, heating or fan only) based on the 
user set point temperature.

•  If the Auto mode is uncomfortable, the desired 

conditions can be selected manually.

Cooling

If there is a demand for cooling, unit will start 
approximately 1 minute after mode is selected.

Heating

•  If there is a demand for heating, unit will start 

approximately 3 to 5 minutes after the mode is 
selected.

•  After the heating operation has stopped, fan may 

continue to run for approx. 30 seconds.

•  When the room temperature reaches the set 

temperature, the outdoor unit stops and the indoor 
unit fan runs at extremely low speed.
During defrost operation, the fan stops so that cool 
air is not discharged. (“ ” Pre-heat is displayed.)

When operation is restarted after stop

When the unit is restarted immediately after it was 
stopped, the unit can not start for approx. 3 minutes 
this is to protect the compressor.

1111056504_EN.indd   14

1111056504_EN.indd   14

9/22/57 BE   3:40 PM

9/22/57 BE   3:40 PM

Summary of Contents for RAV-SM307KRTP-A

Page 1: ...111056504 AIR CONDITIONER SPLIT TYPE Owner s Manual Indoor Unit Model name High Wall Type RAV SM307KRTP A RAV SM407KRTP A For commercial use 1111056504_COVER indd 28 1111056504_COVER indd 28 9 22 57 BE 3 40 PM 9 22 57 BE 3 40 PM ...

Page 2: ...nmentally friendly refrigerant According to IEC 60335 1 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not p...

Page 3: ...work Qualified service person The qualified service person is a person who installs repairs maintains relocates and removes the air conditioners made by Toshiba Carrier Corporation He or she has been trained to install repair maintain relocate and remove the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such operations by an individual or in...

Page 4: ... are completed If there is a danger of the indoor unit s falling do not approach the indoor unit but set the circuit breaker to the OFF position and contact a qualified installer 1 or a qualified service person 1 to refit the unit Do not set the circuit breaker to the ON position until the unit has been refitted If there is a danger of the outdoor unit s toppling over do not approach the outdoor u...

Page 5: ... time Leaving them such condition may result in the unit s falling down and causing injury Do not leave flammable sprays or other flammable materials near the air conditioner and do not spray flammable aerosol directly to the air conditioner They may catch fire Stop running the air conditioner and turn off the breaker before cleaning Otherwise injury may result as the fan is rotating at high speed...

Page 6: ... 6 Limited operation by twin and group combination 3 Preheat Defrost Orange This lamp lights up when the power is turned on or right after heating operation starts or during defrost operation CAUTION Disagreement in operation mode When the power is turned on for the first time after installation lamp lights up for approximately 5 minutes for setting of addresses of systems and units When the power...

Page 7: ...ature is increased up to 30 C TEMP The set temperature is dropped down to 17 C A receiving beep is heard 5 Fan speed button FAN Press this button to select fan speed When you select AUTO the fan speed is automatically adjusted according to the room temperature You can also manually select the desired fan speed from among five settings LOW LOW MED MED HIGH A receiving beep is heard 6 Auto louver bu...

Page 8: ...g is indicated 4 FAN speed display Indicates the selected fan speed AUTO or one of five fan speed levels LOW LOW MED MED HIGH can be indicated Indicates when the operating mode is Dry 5 TIMER and clock time display The time set for timer operation or clock time is indicated The present time is always indicated except for TIMER operation 6 Hi POWER display Indicates when the high power operation st...

Page 9: ...ors or other materials block the signals from the remote controller to the indoor unit Prevent any liquid from falling into the remote controller Do not expose the remote controller to direct sunlight or heat If the infrared signal receiver on the indoor unit is exposed to direct sunlight the air conditioner may not function properly Use curtains to prevent the sunlight from reaching the receiver ...

Page 10: ...eration auto changeover Start PRESET MODE TEMP FAN 2 3 1 4 1 START STOP button Press this button to start the air conditioner 2 Mode select button MODE Select A 3 Temperature button TEMP Set the desired temperature 4 Fan speed button FAN Select one of LOW LOW MED MED HIGH The OPERATION lamp green on the display panel of the indoor unit lights The operating mode is selected in accordance with the r...

Page 11: ... closer to the current time is activated first If the same time is set for both ON and OFF timers no timer operation is performed Also the air conditioner may stop operating Every day combined timer setting both ON and OFF timer simultaneously and activate every day This feature is useful when you want to use combined timer at the same time every day Setting combined TIMER 1 Press the ON TIMER ON ...

Page 12: ...AN ONLY operation NOTE For the cooling operation the set temperature will automatically increase 1 degree hour for 2 hours maximum 2 degrees increase For the heating operation the set temperature will decrease During group control operation the set temperature and the fan speed are not automatically adjusted Only off timer function is activated Sleep timer operation To start the sleep timer OFF ti...

Page 13: ... 5 Wired remote controller This remote controller can control the operation of up to 8 indoor units Display section In the display illustration below all the icons are shown When the unit is in operation only relevant icons will be displayed When the leak breaker is turned on at the first time flashes on the display part of the remote controller While this icon is flashing the model is being autom...

Page 14: ...ture set button Adjusts the set point Select the desired set point by pushing TEMP or TEMP 2 button Timer set button Use to setup the timer 3 button Filter reset button Resets display after cleaning filter 4 button Test button Use only for service During normal operation do not use this button 5 button When the button is pushed the operation starts and it stops by pushing the button again When the...

Page 15: ...used for a long period turn on the circuit breaker at least 12 hours before starting the air conditioner SET TIME TIMER SET TEST FILTER RESET TEMP CL FAN SAVE SWING FIX VENT MODE ON OFF UNIT LOUVER 1 3 2 4 Start 1 Push button The operation lamp illuminates and the operation starts 2 Select an operation mode with the button One push of the button and the display changes in the order shown below Aut...

Page 16: ...n after about 5 seconds This is due to normal processing of the remote controller 5 3 Power saving mode The power saving mode saves energy by limiting the maximum current which will effect heating or cooling capacity that the unit can generate Push button during operation The air conditioner enters power saving mode appears on the display Power saving mode will stay in effect until it is cancelled...

Page 17: ...mote controller Remote controller Indoor Indoor Indoor Example of group combination CAUTION When using indoor unit in group control 1 Hi POWER operation will not function When Hi POWER is transmitted from wireless remote controller the receiving sound will be heard from the indoor unit and display on the wireless remote controller will also change However the indoor unit does not operate Hi POWER ...

Page 18: ... AUTO mode is uncomfortable the desired conditions can be selected manually Hi POWER operation When the Hi POWER button is pushed during cooling heating or AUTO operation the air conditioner will start the following operation Cooling operation Performs the cooling operation at 1 C lower than the setting temperature Only when the fan speed before the Hi POWER operation is not high the fan speed wil...

Page 19: ...ose burden on the air conditioner Do not perform this for the purposes other than test run In this time all indicators of indoor unit go on 11Maintenance WARNING Before cleaning the air conditioner to turn off the circuit breaker or main power switch After the cooling or dry auto cooling operation has finished the self clean operation is performed and the fan starts running Before cleaning the uni...

Page 20: ...completely closed When not used for a long time 1 Perform the fan operation for a couple of hours to dry inside 2 Push button on the remote controller to stop running and turn off the circuit breaker 3 Clean the air filters and reinstall them Before the cooling season Clean the drain pan Contact the dealer where you purchased the product Drain does not work if the drain pan or vent is clogged In s...

Page 21: ...er the unit starts running This is the sound of the refrigerant flowing or the dehumidifier draining A clacking sound is heard This is a sound generated when the heat exchanger or other part expands and contracts slightly due to temperature change Discharged air smells unusual Various smells from the walls carpet clothes cigarette cosmetics or other things adhere to the air conditioner The fan con...

Page 22: ...sh the ON OFF button on the remote controller to restart Defrosting operation If the outdoor unit is frosted during the heating operation defrosting starts automatically for approximately 2 to 10 minutes to maintain the heating capacity The fans in both indoor and outdoor units will stop during the defrosting operation During the defrosting operation the defrosted water will be drained from the bo...

Page 23: ...d to strong wind such as in seaside area Do not install the air conditioner in a place where sulfureous gas generated such as in a spa Do not install the air conditioner in a vessel or mobile crane Do not install the air conditioner in an acidic or alkaline atmosphere in a hot spring area or near a chemicals factory or in a place subject to combustion emissions Corrosion may be generated on the al...

Page 24: ...111056504 144 9 Moo 5 Bangkadi Industrial Park Tivanon Road Tambol Bangkadi Amphur Muang Pathumthani 12000 Thailand 1111056504_COVER indd 29 1111056504_COVER indd 29 9 22 57 BE 3 40 PM 9 22 57 BE 3 40 PM ...

Reviews: