background image

– 21 –

 

Con

fi

rmation and check

When an error occurred in the air conditioner, an error 
code and indoor UNIT No. appear on the display part 
of the remote controller.
The error code is only displayed during the operation. 
If the display disappears, operate the air conditioner 
according to the following “Confirmation of error log” 
for confirmation.

Error code

Indoor UNIT No. in 
which an error occurred

 

Con

fi

rmation of error log

When an error occurred on the air conditioner, 
the error log can be confirmed with the following 
procedure.
(The error log is stored in memory up to 4 errors.) The 
log can be confirmed from both operating status and 
stop status.

3

2

1

1

 Push  and   buttons simultaneously for 

4 seconds or more, the following display 
appears.

If   is displayed, the mode enters in the error log 
mode.
• [

01

: Order of error log] is displayed in CODE 

No..

•  [Error code] is displayed in CHECK.
•  [Indoor unit address in which an error occurred] 

is displayed in Unit No..

2

  Every pushing of 

 button used to 

set temperature, the error log stored in 
memory is displayed in order.

The numbers in CODE No. indicate CODE No.
[

01

] (latest) 

 [

04

] (oldest).

REQUIREMENT

Do not push   button because all the error log of the 
indoor unit will be deleted.

3

 After 

con

fi

rmation, push   button to return 

to the usual display.

13 

Operations and performance

 

Check before running

•  Check whether the earth wire is cut or disconnected.
•  Check whether the air 

fi

 lter is installed.

•  Turn on the circuit breaker 12 hours or more before starting operation.

 

3 minutes protection function

3-minutes protection function prevents the air conditioner from starting for initial 3 minutes after the main power 
switch / circuit breaker is turned on for re-starting the air conditioner.

 

Power failure

Power failure during operation will stop the unit completely.
•  To restart the operation, push the ON / OFF button on the remote controller.
•  Lightning or a wireless car telephone operating nearby may cause the unit to malfunction. Turn off the main 

power switch or circuit breaker and then turn them on again. Push the ON / OFF button on the remote controller 
to restart.

 

Defrosting operation

If the outdoor unit is frosted during the heating operation, defrosting starts automatically (for approximately 2 to 10 
minutes) to maintain the heating capacity.
•  The fans in both indoor and outdoor units will stop during the defrosting operation.
•  During the defrosting operation, the defrosted water will be drained from the bottom plate of the outdoor unit.

 

Heating capacity

In the heating operation, the heat is absorbed from the outside and brought into the room. This way of heating 
is called heat pump system. When the outside temperature is too low, it is recommended to use another heating 
apparatus in combination with the air conditioner.

 

 Protective device

•  Stops operation when the air-conditioner is overloaded.
•  If the protective device is activated, the unit stops running, and the operation indicator and check indicator on 

the remote controller blink.

 

If the protective device is activated

•  Turn off the circuit breaker and perform a checkup.

Continued running may cause a malfunction.

•  Check whether the air 

fi

 lter is installed. If not, the heat exchanger may be clogged with dust and water leakage 

may occur.

 

During cooling

•  The air intake or discharge of the outdoor unit is clogged.
•  Strong wind continuously blows against the discharge of the outdoor unit.

 

During heating

• The air 

fi

 lter is clogged with a large amount of dust.

•  The air intake or discharge of the indoor unit is clogged.

 

Do not turn off the circuit breaker

•  During the air-conditioning season, leave the circuit breaker turned on, and use the ON / OFF key on the remote 

controller.

 

Attention to snowfall and freeze on the outdoor unit

•  In snowy areas, the air intake and air discharge of the outdoor unit are often covered with snow or frozen up.

If snow or freeze on the outdoor unit is left as it is, it may cause machine failure or poor warming.

•  In cold areas, pay attention to the drain hose so that it perfectly drains water without water remaining inside for 

freeze prevention. If water freezes in the drain hose or inside the outdoor unit, it may cause machine failure or 
poor warming.

41-EN

42-EN

1111056504_EN.indd   21

1111056504_EN.indd   21

9/22/57 BE   3:40 PM

9/22/57 BE   3:40 PM

Summary of Contents for RAV-SM307KRTP-A

Page 1: ...111056504 AIR CONDITIONER SPLIT TYPE Owner s Manual Indoor Unit Model name High Wall Type RAV SM307KRTP A RAV SM407KRTP A For commercial use 1111056504_COVER indd 28 1111056504_COVER indd 28 9 22 57 BE 3 40 PM 9 22 57 BE 3 40 PM ...

Page 2: ...nmentally friendly refrigerant According to IEC 60335 1 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not p...

Page 3: ...work Qualified service person The qualified service person is a person who installs repairs maintains relocates and removes the air conditioners made by Toshiba Carrier Corporation He or she has been trained to install repair maintain relocate and remove the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such operations by an individual or in...

Page 4: ... are completed If there is a danger of the indoor unit s falling do not approach the indoor unit but set the circuit breaker to the OFF position and contact a qualified installer 1 or a qualified service person 1 to refit the unit Do not set the circuit breaker to the ON position until the unit has been refitted If there is a danger of the outdoor unit s toppling over do not approach the outdoor u...

Page 5: ... time Leaving them such condition may result in the unit s falling down and causing injury Do not leave flammable sprays or other flammable materials near the air conditioner and do not spray flammable aerosol directly to the air conditioner They may catch fire Stop running the air conditioner and turn off the breaker before cleaning Otherwise injury may result as the fan is rotating at high speed...

Page 6: ... 6 Limited operation by twin and group combination 3 Preheat Defrost Orange This lamp lights up when the power is turned on or right after heating operation starts or during defrost operation CAUTION Disagreement in operation mode When the power is turned on for the first time after installation lamp lights up for approximately 5 minutes for setting of addresses of systems and units When the power...

Page 7: ...ature is increased up to 30 C TEMP The set temperature is dropped down to 17 C A receiving beep is heard 5 Fan speed button FAN Press this button to select fan speed When you select AUTO the fan speed is automatically adjusted according to the room temperature You can also manually select the desired fan speed from among five settings LOW LOW MED MED HIGH A receiving beep is heard 6 Auto louver bu...

Page 8: ...g is indicated 4 FAN speed display Indicates the selected fan speed AUTO or one of five fan speed levels LOW LOW MED MED HIGH can be indicated Indicates when the operating mode is Dry 5 TIMER and clock time display The time set for timer operation or clock time is indicated The present time is always indicated except for TIMER operation 6 Hi POWER display Indicates when the high power operation st...

Page 9: ...ors or other materials block the signals from the remote controller to the indoor unit Prevent any liquid from falling into the remote controller Do not expose the remote controller to direct sunlight or heat If the infrared signal receiver on the indoor unit is exposed to direct sunlight the air conditioner may not function properly Use curtains to prevent the sunlight from reaching the receiver ...

Page 10: ...eration auto changeover Start PRESET MODE TEMP FAN 2 3 1 4 1 START STOP button Press this button to start the air conditioner 2 Mode select button MODE Select A 3 Temperature button TEMP Set the desired temperature 4 Fan speed button FAN Select one of LOW LOW MED MED HIGH The OPERATION lamp green on the display panel of the indoor unit lights The operating mode is selected in accordance with the r...

Page 11: ... closer to the current time is activated first If the same time is set for both ON and OFF timers no timer operation is performed Also the air conditioner may stop operating Every day combined timer setting both ON and OFF timer simultaneously and activate every day This feature is useful when you want to use combined timer at the same time every day Setting combined TIMER 1 Press the ON TIMER ON ...

Page 12: ...AN ONLY operation NOTE For the cooling operation the set temperature will automatically increase 1 degree hour for 2 hours maximum 2 degrees increase For the heating operation the set temperature will decrease During group control operation the set temperature and the fan speed are not automatically adjusted Only off timer function is activated Sleep timer operation To start the sleep timer OFF ti...

Page 13: ... 5 Wired remote controller This remote controller can control the operation of up to 8 indoor units Display section In the display illustration below all the icons are shown When the unit is in operation only relevant icons will be displayed When the leak breaker is turned on at the first time flashes on the display part of the remote controller While this icon is flashing the model is being autom...

Page 14: ...ture set button Adjusts the set point Select the desired set point by pushing TEMP or TEMP 2 button Timer set button Use to setup the timer 3 button Filter reset button Resets display after cleaning filter 4 button Test button Use only for service During normal operation do not use this button 5 button When the button is pushed the operation starts and it stops by pushing the button again When the...

Page 15: ...used for a long period turn on the circuit breaker at least 12 hours before starting the air conditioner SET TIME TIMER SET TEST FILTER RESET TEMP CL FAN SAVE SWING FIX VENT MODE ON OFF UNIT LOUVER 1 3 2 4 Start 1 Push button The operation lamp illuminates and the operation starts 2 Select an operation mode with the button One push of the button and the display changes in the order shown below Aut...

Page 16: ...n after about 5 seconds This is due to normal processing of the remote controller 5 3 Power saving mode The power saving mode saves energy by limiting the maximum current which will effect heating or cooling capacity that the unit can generate Push button during operation The air conditioner enters power saving mode appears on the display Power saving mode will stay in effect until it is cancelled...

Page 17: ...mote controller Remote controller Indoor Indoor Indoor Example of group combination CAUTION When using indoor unit in group control 1 Hi POWER operation will not function When Hi POWER is transmitted from wireless remote controller the receiving sound will be heard from the indoor unit and display on the wireless remote controller will also change However the indoor unit does not operate Hi POWER ...

Page 18: ... AUTO mode is uncomfortable the desired conditions can be selected manually Hi POWER operation When the Hi POWER button is pushed during cooling heating or AUTO operation the air conditioner will start the following operation Cooling operation Performs the cooling operation at 1 C lower than the setting temperature Only when the fan speed before the Hi POWER operation is not high the fan speed wil...

Page 19: ...ose burden on the air conditioner Do not perform this for the purposes other than test run In this time all indicators of indoor unit go on 11Maintenance WARNING Before cleaning the air conditioner to turn off the circuit breaker or main power switch After the cooling or dry auto cooling operation has finished the self clean operation is performed and the fan starts running Before cleaning the uni...

Page 20: ...completely closed When not used for a long time 1 Perform the fan operation for a couple of hours to dry inside 2 Push button on the remote controller to stop running and turn off the circuit breaker 3 Clean the air filters and reinstall them Before the cooling season Clean the drain pan Contact the dealer where you purchased the product Drain does not work if the drain pan or vent is clogged In s...

Page 21: ...er the unit starts running This is the sound of the refrigerant flowing or the dehumidifier draining A clacking sound is heard This is a sound generated when the heat exchanger or other part expands and contracts slightly due to temperature change Discharged air smells unusual Various smells from the walls carpet clothes cigarette cosmetics or other things adhere to the air conditioner The fan con...

Page 22: ...sh the ON OFF button on the remote controller to restart Defrosting operation If the outdoor unit is frosted during the heating operation defrosting starts automatically for approximately 2 to 10 minutes to maintain the heating capacity The fans in both indoor and outdoor units will stop during the defrosting operation During the defrosting operation the defrosted water will be drained from the bo...

Page 23: ...d to strong wind such as in seaside area Do not install the air conditioner in a place where sulfureous gas generated such as in a spa Do not install the air conditioner in a vessel or mobile crane Do not install the air conditioner in an acidic or alkaline atmosphere in a hot spring area or near a chemicals factory or in a place subject to combustion emissions Corrosion may be generated on the al...

Page 24: ...111056504 144 9 Moo 5 Bangkadi Industrial Park Tivanon Road Tambol Bangkadi Amphur Muang Pathumthani 12000 Thailand 1111056504_COVER indd 29 1111056504_COVER indd 29 9 22 57 BE 3 40 PM 9 22 57 BE 3 40 PM ...

Reviews: