To automatically swing the air
fl
ow
direction
Perform this function when the air conditioner is in
operation.
PRESET
QUIET
SWING
FIX
Hi-POWER
COMFORT
SLEEP
MODE
TEMP
FAN
1
1
SWING
button
Press the SWING button on the remote controller.
• To stop the function, press the SWING button.
CAUTION
• The FIX and SWING buttons will be disabled when
the air conditioner is not in operation (including
when the ON timer is set).
• Do not operate the air conditioner for long hours
withthe air
fl
ow direction set downward during the
coolingor dry operation.
Otherwise, condensation may occur on the surface
of the vertical air
fl
ow louver and cause dew
dripping.
• Do not move the vertical air
fl
ow louver manually.
Always use the FIX button.
If you move the louver manually, it may
malfunction during operation.
If the louver malfunctions, stop the air conditioner
once, and restart.
• When the air conditioner is started immediately
after it was stopped, the vertical air
fl
ow louver
might not move for 10 seconds or so.
• Louver operation is limited when performing group
control. (see page 16)
■
Adjust the horizontal air
fl
ow
◆
Preparation
• Take hold of the lever on the horizontal air
fl
ow
louver and move them to adjust the air
fl
ow direction
as required.
• You can adjust the air
fl
ow at the left, and right
locations of the louver.
5
Wired remote controller
This remote controller can control the operation of up to 8 indoor units.
■
Display section
In the display illustration below all the icons are shown. When the unit is in
operation, only relevant icons will be displayed.
• When the leak breaker is turned on at the
fi
rst time,
fl
ashes on the
display part of the remote controller.
• While this icon is
fl
ashing, the model is being automatically con
fi
rmed.
Wait till
icon has disappeared to use the remote controller.
1
10
6
19
4
2
3
5
7
15
17
16 20
11
14
13
12
8 9
18
SET
TIME
TIMER SET
TEST
FILTER
RESET
TEMP.
CL
FAN
SAVE
SWING/FIX
VENT
MODE
ON / OFF
UNIT LOUVER
Display
section
Operation
section
1
Operation
mode
The selected operation mode is displayed.
2
Error
display
Displayed while the protective device works or a
error occurs.
3
SETTING
display
Displayed during setup of the timer or other
settings.
4
TEST run display
Displayed during a test run.
5
Timer
display
When an error occurs, error code is displayed.
6
Timer mode display
The selected timer mode is displayed.
7
Filter
display
Reminder to clean the air
fi
lter.
8
Louver position display
Displays louver position.
9
SWING
display
Displayed during up / down movement of the
louver.
10
Fan speed display
The selected fan speed mode is displayed.
(AUTO)
(HIGH)
(MED.)
(LOW)
11
Set temperature display
The selected set temperature is displayed.
12
Power saving mode display
Limits compressor speed (capacity) to save
energy.
1111056504_EN.indd 12
1111056504_EN.indd 12
9/22/57 BE 3:40 PM
9/22/57 BE 3:40 PM