8.
Press
& hold 4s
ec.
Set
the “
p
re
ss and
hold”
ope
rat
io
n
for
the
[
Lit
e
-V
is
ion
plus Remot
e
C
ontro
ll
er
Installation
Manual
ON /
OF
F] b
u
tton.
1
Push the [
∧
] /
[
∨
] button t
o
select
“
8. Press & hold 4sec.
”
on the “
In
it
ial
se
tti
ng
”
scr
een, then pu
s
h
the “
Set” [
F2] bu
tton.
2
Push the [
∧
] /
[
∨
] button t
o
select
“
O
N” o
r
“OFF”.
3
Push the [
MEN
U
] butto
n.
Æ
W
hen “
ON” is selected
, the
air-
conditione
r
star
ts / sto
p
s r
unning
wh
en th
e [
ON
/ OFF
]
bu
tton
is pr
essed
and h
o
ld 4 se
c
o
nds.
Æ
W
hen “
O
FF”
is selected,
the a
ir
-c
o
nditione
r
star
ts / sto
p
s r
unning
wh
en th
e [
ON
/ OFF
]
bu
tton is
pr
essed
.
Initial setting(2/2)
6.Header/Follower
7.Language
8.Press & hold 4 sec.
Set
Return
Press & hold 4sec.
ON
OFF
Return
Fix
Set
Lit
e
-V
is
ion
plus Remot
e
C
ontro
ller
Installation
Manual
Field setting menu
1.
Te
st Mode
Set
for the t
e
st ope
rat
io
n
afte
r insta
llation
.
B
e
fo
re t
h
e te
st m
ode
•
Per
for
m
the
followin
g
s befo
re
tur
n
in
g on
the p
o
wer:
1)
B
y
usin
g 500
V-
meg
ger
, check tha
t re
sista
nce of 1
M
Ω
or
mo
re
exists b
etween
the te
rm
in
al block of th
e
p
ower
s
u
pply and
the e
art
h (
ear
thing)
.
If r
e
si
stan
ce of less th
an 1
M
Ω
is d
etected
, do
not r
un
the un
it
.
2)
Che
c
k a
ll valve o
f the o
u
tdo
o
r
unit is open
ed fu
lly.
•
T
o
pr
otect th
e com
pre
s
s
o
r a
t the
tim
e of
star
tup, lea
v
e
the
power
on fo
r 1
2 hou
rs or
m
or
e befo
re
oper
ation
.
•
D
o not
pr
ess the electr
oma
gnetic c
o
ntacto
r to for
c
ibly
per
for
m
the test mo
de. (I
t
is
ve
ry dang
ero
u
s
b
e
cause the
pro
tective device d
oes not
wo
rk.)
Performi
ng the
test mode
For
the p
ro
c
e
dur
e of
the op
er
ation, r
efe
r to
the
s
u
pp
lied Owner
’s Man
ual. A fo
rced
test m
ode
c
a
n be
per
for
m
ed
according t
o
the
followin
g
procedu
re
wh
en th
e room temperature ri
ses / fa
lls en
ough
for the
thermostat to
turn o
ff.
In or
der
to
p
re
v
e
n
t a c
o
ntinuou
s
op
era
tion, the for
c
ed te
st ope
rat
io
n
is re
lea
s
ed after
60 minut
es
h
ave
p
assed and
retur
ns to
the no
rm
al ope
rat
io
n.
CA
UT
IO
N
Do
no
t pe
rfo
rm
th
e fo
rce
d
t
e
st m
o
d
e
f
o
r pu
rpo
s
es
oth
e
r tha
n
t
he
test
mo
de
be
cau
s
e it
app
lies a
n
e
xce
ssive
load
to
the
d
e
vice
s.
1
Push the [
MEN
U]
but
to
n t
o
di
s
p
la
y
the
m
e
nu scr
een.
2
Push and
hol
d the [
MENU
] button and
the
[
∨
]
butt
o
n
at the same
time to
displ
a
y
the “Fi
e
ld
setting
menu”.
Æ
Pu
s
h
and
hold th
e butt
ons for
m
o
re
than
4
secon
d
s.
3
Push the [
CA
NCEL
] button to return.
It
em
Functi
on
1. Test
m
ode
Settings for when
p
erform
in
g
the
tes
t oper
ation after
instal
lati
on
2. Regi
s
ter
s
ervice i
nfo
Registrati
on
of inform
ation ab
out the co
n
tact num
ber
for
service, m
odel name
a
n
d
se
rial
num
ber of
the i
n
d
oor unit and outdoor unit
3. Al
ar
m history
List of
la
test 10
alarm
dat
a
: err
o
r in
for
m
at
io
n
o
f check code
, dat
e
, ti
m
e
, and uni
t
4. Mo
ni
tor functi
on
M
onitor
in
g
data
o
f sen
sor temp
erature
, ro
tati
n
g
speed of th
e com
p
ress
or or
othe
r
fa
ct
or.
5.
DN
s
e
tt
ing
Adva
nced settings using D
N
code
FILE NO. SVM-18059
- 107 -