![Toshiba RAV-GM 1101UT-E Service Manual Download Page 35](http://html.mh-extra.com/html/toshiba/rav-gm-1101ut-e/rav-gm-1101ut-e_service-manual_1135185035.webp)
– 35 –
RAV-GP801 series
Pressure
Pipe surface temperature (˚C)
Compressor
drive revolution
frequency (rps)
indoor
fan
Indoor/outdoor
temp.condition
(Mpa)
(kg/cm
2
g) Discharge suction
indoor heat
exchanger
Outdoor heat
exchanger
Pd
Ps
Pd
Ps
(TS)
(TD)
(TC)
(TL)
(TE)
indoor outdoor
2.7
3.8
2.5
2.1
3.6
1.6
1.1
1.2
0.9
0.7
1.2
0.2
cooling
Heating
Standard
Overload
Low load
Standard
Overload
Low load
27.9
38.7
25.5
21.2
36.9
16.6
11.0
12.5
9.3
7.3
12.7
1.7
71.7
80.2
45.2
66.1
88.7
53.1
15.6
20.1
7.1
4.7
18.2
-26.6
14.0
19.0
8.0
32.0
53.0
22.0
46.8
59.5
44.0
9.1
20.0
-10.5
43.0
57.2
37.6
3.3
17.4
-25.7
48.0
44.4
30.0
60.0
24.0
99.6
HIGH
HIGH
LOW
HIGH
LOW
HIGH
27/19
32/24
18/15.5
20/-
30/-
15/-
35/-
52/-
-15/-
7/6
24/18
-27/-
Pressure
Pipe surface temperature (˚C)
Compressor
drive revolution
frequency (rps)
indoor
fan
Indoor/outdoor
temp.condition
(Mpa)
(kg/cm
2
g) Discharge suction
indoor heat
exchanger
Outdoor heat
exchanger
Pd
Ps
Pd
Ps
(TS)
(TD)
(TC)
(TL)
(TE)
indoor outdoor
2.5
3.6
1.9
2.2
3.6
1.5
1.1
1.4
0.7
0.8
1.1
0.2
cooling
Heating
Standard
Overload
Low load
Standard
Overload
Low load
25.5
37.0
19.5
22.7
36.3
15.7
11.3
14.0
6.9
7.8
11.3
1.8
73.1
77.4
70.3
72.6
90.8
64.7
15.6
21.4
1.2
3.9
23.5
-25.7
14.0
21.0
3.0
35.0
53.0
21.0
44.0
58.5
39.9
9.1
23.0
-10.5
36.3
54.5
30.3
3.9
18.2
-24.4
34.2
30.0
33.0
44.4
26.4
78.6
HIGH
HIGH
LOW
HIGH
LOW
HIGH
27/19
32/24
18/15.5
20/-
30/-
15/-
35/-
52/-
-15/-
7/6
24/18
-27/-
Pressure
Pipe surface temperature (˚C)
Compressor
drive revolution
frequency (rps)
indoor
fan
Indoor/outdoor
temp.condition
(Mpa)
(kg/cm
2
g) Discharge suction
indoor heat
exchanger
Outdoor heat
exchanger
Pd
Ps
Pd
Ps
(TS)
(TD)
(TC)
(TL)
(TE)
indoor outdoor
2.7
3.6
1.9
2.5
3.6
1.6
1.0
1.4
0.7
0.7
1.1
0.2
cooling
Heating
Standard
Overload
Low load
Standard
Overload
Low load
27.7
37.0
19.5
25.2
36.3
16.7
10.0
14.0
6.9
7.5
11.3
1.6
84.6
77.4
70.3
83.2
90.8
65.6
16.0
21.4
1.2
3.9
23.5
-27.0
11.0
21.0
3.0
38.0
53.0
23.0
46.3
58.5
39.9
7.6
23.0
-10.5
36.3
54.5
30.3
3.6
18.2
-24.8
47.4
30.0
33.0
55.8
26.4
99.6
HIGH
HIGH
LOW
HIGH
LOW
HIGH
27/19
32/24
18/15.5
20/-
30/-
15/-
35/-
52/-
-15/-
7/6
24/18
-27/-
* This compressor has a 6-pole motor
The value when compressor frequency (Hz) is measured by a clamp meter is 3 times the compressor
revolution number (rps)
* This data is cycle data obtained by combining a four-way cassette type.
Data will change depending on the mounted pipe length or combination with the indoor unit.
RAV-GP1101 series
RAV-GP1401 series
* This compressor has a 4-pole motor
The value when compressor frequency (Hz) is measured by a clamp meter is twice the compressor
revolution number (rps)
* This data is cycle data obtained by combining a four-way cassette type.
Data will change depending on the mounted pipe length or combination with the indoor unit.
Summary of Contents for RAV-GM 1101UT-E
Page 30: ... 30 2 CONSTRUCTION VIEWS EXTERNAL VIEWS 2 1 RAV GP801AT ...
Page 31: ... 31 2 2 RAV GP1101AT GP1401AT ...
Page 36: ... 36 4 WIRING DIAGRAM 4 1 RAV GP801AT 220 240V 50Hz P 3 3 Fuse 25A 250V Fuse 10A 250V ...
Page 37: ... 37 4 2 RAV GP1101AT GP1401AT 220 240V 50Hz P 3 3 3 Fuse 25A 250V Fuse 10A 250V ...