Item
18. One Touch
Comfort
Operation flow and applicable data, etc.
One touch comfort is the fully automated operation that
is set according to the preferable condition in a region.
Description
Operation condition for model to
Europe market
When an indoor unit receives “One
Touch Comfort Signal” from the
remote controller, the indoor unit
operates as following.
1) Air conditioner starts to operation
when the signal is received, even if
the air conditioner was OFF.
2) Operation mode is set according to
room temperature, the same as
AUTO mode.
3) Target temperature is 24°C.
4) Louver position is set as stored
position of the operating mode.
5) Fan is controlled as followings.
∗
AUTO/L: Fan operates depends on the setting
temperature and room temperature.
During the One Touch Comfort mode if the indoor unit
receives any signal with other operation mode, the
unit will cancel the comfort mode and operates
according to the signal received.
([Hi-POWER] button on the remote controller is
pushed)
When [Hi-POWER] button is pushed while the indoor
unit is in Auto, Cooling or Heating operation, Hi
POWER mark is indicated on the display of the remote
controller and the unit operates as follows.
1. Automatic operation
• The indoor unit operates in according to the
current operation.
2. Cooling operation
• The preset temperature drops 1 degree
(The value of the preset temperature on the
remote controller does not change.)
The indoor unit’s fan speed level increases 1 tap.
3. Heating operation
• The preset temperature increases 2 degree
(The value of the preset temperature on the
remote controller does not change.)
The indoor unit’s fan speed level increases 1 tap
4. The Hi POWER mode can not be set in Dry
operation
When the elapsed time reaches 1000 hours after
air conditioner
operation, the FILTER indicator lights.
After cleaning the filters, turn off the FILTER indicator.
How to Turn Off FILTER Indicator
Push [RESET] button on the indoor unit.
NOTE :
If [RESET] button is pushed while the FILTER indicator
is not lit, the indoor unit will start the automatic
operation.
When you want a temporary operation while the
FILTER lamp lights, push [RESET] button to turn off
the FILTER lamp.
19. Hi POWER Mode
20. FILTER Indicator
0
12
25
AUTO
*AUTO/L L
Fan
Operation
Time after operation
starts (min)
FILE NO. SVM-12056
–
42
–
Summary of Contents for RAS-18N3AV2-E
Page 108: ...TOSHIBA CARRIER THAILAND CO LTD ...