E6582051
- 48 -
7.7.
"43 (0x2B) Read Device identification" function
The Modbus request is used to read the device identification.
Example in VF-S15 is shown below.
Request format:
Byte Meaning
0
Function Code =
2Bh
2Bh
1
Type of MEI
0Eh
2
Read Device ID code
01: Basic
02: Regular
03: Extended
3 Object
ID
0
Response format: (ID = 0 - 248)
Byte
Meaning
With the PNE001Z
0
Function Code =
2Bh
2Bh
1
Type of MEI
0Eh
2
Read Device ID code
01: Basic
02: Regular
03: Extended
3 Conformity
Level
2
4 More
Follows
0
5
Next Object Id
0
6
Number Of Objects
3 for Basic.
6 for Regular or Extended
7
Obj 0 Id
Vendor Name
0
8
Obj 0 length
7
9-15
Obj 0 value
“TOSHIBA”
16
Obj 1 Id
ProductCode
1
17
Obj 1 length
13
18-30
Obj 1 value
“VFS15-2004PM”
31
Obj 2 Id
Version
2
32
Obj 2 length
5
33-37
Obj 2 value
“11200”
38
Obj 4 Id
Product Name
4
Only for
Regular
and
Extended
39
Obj 4 length
6
40-45
Obj 4 value
“VF-S15”
46
Obj 5 Id
Model Name
5
47
Obj 5 length
3
44-58
Obj 5 value
“TSB”
59
Obj 6 Id
UserApplicationName
6
60
Obj 6 length
16 maximum
61-80
Obj 6 value
“PROFINET”