Flow Selector unit Multi-port type (12 ports and 8 ports type) In case that connection pipe length on the
downstream side is 180 m. (Connection pipe length on the downstream side is total length of each port)
Installation permitted
Installation permitted
Minimum
fl
oor area A
min
[m
2
]
Ceiling mounted type (include duct type)
Minimum
fl
oor area A
min
[m
2
]
Wall mount and under ceiling type
Total capacity of indoor units on the
downstream side of the shut-of
f valve [HP]
Total capacity of indoor units on the
downstream side of the shut-of
f valve [HP]
Installation
not permitted
Installation
not permitted
■
Flow Selector unit Multi-port type (4 ports type) In case that connection pipe length on the downstream side is
120 m. (Connection pipe length on the downstream side is total length of each port)
Installation permitted
Installation permitted
Minimum
fl
oor area A
min
[m
2
]
Ceiling mounted type (include duct type)
Minimum
fl
oor area A
min
[m
2
]
Wall mount and under ceiling type
Total capacity of the indoor units on the
downstream side of the shut-of
f valve [HP]
Total capacity of the indoor units on the
downstream side of the shut-of
f valve [HP]
Installation
not permitted
Installation
not permitted
■
Flow Selector unit Single-port type (4 HP type) In case that connection pipe length on the downstream side is
50 m.
Installation permitted
Installation permitted
Minimum
fl
oor area A
min
[m
2
]
Ceiling mounted type (include duct type)
Minimum
fl
oor area A
min
[m
2
]
Wall mount and under ceiling type
Total capacity of the indoor units on the
downstream side of the shut-of
f valve [HP]
Total capacity of the indoor units on the
downstream side of the shut-of
f valve [HP]
Installation
not permitted
Installation
not permitted
■
Flow Selector unit Single-port type (6.4 HP type) In case that connection pipe length on the downstream side is
50 m.
Installation permitted
Installation permitted
Minimum
fl
oor area A
min
[m
2
]
Ceiling mounted type (include duct type)
Minimum
fl
oor area A
min
[m
2
]
Wall mount and under ceiling type
Total capacity of the indoor units on the
downstream side of the shut-of
f valve [HP]
Total capacity of the indoor units on the
downstream side of the shut-of
f valve [HP]
Installation
not permitted
Installation
not permitted
■
Flow Selector unit Single-port type (10 HP type) In case that connection pipe length on the downstream side is
50 m.
Installation permitted
Installation permitted
Minimum
fl
oor area A
min
[m
2
]
Ceiling mounted type (include duct type)
Minimum
fl
oor area A
min
[m
2
]
Wall mount and under ceiling type
Total capacity of the indoor units on the
downstream side of the shut-of
f valve [HP]
Total capacity of the indoor units on the
downstream side of the shut-of
f valve [HP]
Installation
not permitted
Installation
not permitted
• Shut-off Valve unit
The installation availability line differs depending on the Shut-off Valve unit type (horsepower) and the length of
the connecting pipe.
Example) Every 100 m connections from maximum to
minimum connection (4 HP)
Every 100 m connections from maximum to minimum
connection (6.4 HP)
Minimum
fl
oor area A
min
[m
2
]
Ceiling mounted type (include duct type)
Pipe
10 m
Pipe
10 m
Pipe
100 m
Pipe
100 m
Pipe
200 m
Pipe
200 m
Pipe
300 m
Pipe
300 m
Pipe
400 m
Pipe
400 m
Pipe
500 m
Pipe
500 m
Minimum
fl
oor area A
min
[m
2
]
Ceiling mounted type (include duct type)
Total capacity of the indoor units on the
downstream side of the shut-of
f valve [HP]
Total capacity of the indoor units on the
downstream side of the shut-of
f valve [HP]
installation not permitted
installation not permitted
Installation
permitted
Installation
permitted
Every 100 m connections from maximum to minimum
connection (24 HP)
Minimum
fl
oor area A
min
[m
2
]
Ceiling mounted type (include duct type)
Pipe
10 m
Pipe
100 m
Pipe
200 m
Total capacity of the indoor units on the
downstream side of the shut-of
f valve [HP]
installation
not permitted
Installation
permitted
پ
Please refer to the attached “Installation data” for graphs and numerical values in other cases.
پ
For units to which the Shut-off Valve unit (24 HP type) is connected and the system refrigerant amount exceeds
30 kg, the following restrictions shall be set on the main pipe length on the outdoor unit side of the Shut-off
Valve unit.
(Main piping length on the outdoor unit side of the Shut-off Valve unit)
≥
(total system refrigerant amount - 30 kg) × 3 m
If the main pipe length exceeds 40 m, it will not be restricted beyond that.