8-EN
Installation plate
300 mm or more
300 mm or more
Shield pipe
300 mm or more
–8–
Toshiba 1112750201 (EN)
Installation Manual
Installation diagram of indoor and outdoor units
Batteries
Insulate the refrigerant pipes separately
with insulation, not together.
8 mm thick heat resisting
polyethylene foam
Mounting screw
Wireless remote control
Pan head wood screw
Remote control holder
Do not allow the drain hose to get slack.
Make sure to run the drain hose sloped
downward.
Cut the piping
hole sloped
slightly.
Cut dot-line area
In case of right or left piping
Heat insulator
Air fi lter
Installation place
•
A place which provides the spaces around the indoor unit as shown in the diagram.
•
A place where there are no obstacles near the air inlet and outlet.
•
A place which allows easy installation of the piping to the outdoor unit.
•
A place which allows the front panel to be opened.
CAUTION
• Direct sunlight to the indoor unit’s wireless receiver should be avoided.
• The microprocessor in the indoor unit should not be too close to RF noise sources.
(For details, see the owner’s manual.)
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Right
Left
Bottom right Rear
left
Bottom left
Rear right
Summary of Contents for MML-AP0074NH-E