Chapter 7 Application Interface
6F8C1399
58
7.1 Usage Constraints
7.1.1 Constraint on the number of units installed
Up to 16 special modules such as the MD911 module can be installed to one
controller.
The I/O module for an output cannot be installed on the same TC-net I/O bus.
The I/O modules for an input can be installed.
7.1.2 Combination of firmware version
MD911 operates in the combination of the following firmware.
PU811/866 Firmware (SHTYPE1A) V01.45 or later.
PU821 Firmware (SHTYPE2A) V01.50 or later.
SA911/SA912 Firmware (SESIO91A) V01.21 or later.
SA911/SA912 Firmware (SESIO91B) V02.21 or later.
Engineering tool (Japanese) Client-server (HET82J4SS) V4.7.0 or later
Engineering tool (English) Client-server (HET82E4SS) V4.7.0 or later
Engineering tool (Japanese) Stand-alone (HET81J4SS) V4.7.0 or later
Engineering tool (Japanese) Stand-alone (HET81E4SS) V4.7.0 or later