Toshiba MCY-MHP0806HS8-E Owner'S Manual Download Page 13

Owner’s Manual

– 12 –

EN

Operation section

Once the settings have been configured, all you need to do is push the 

 button from then on.

1

 button (Fan speed select button)

Selects the desired Fan speed.
* Not available for the concealed duct high static 

pressure. Only “High” is displayed.

2

 button (Timer set button)

Use to setup the timer.

3

 button (TEST button)

Use only for service. 
(During normal operation, do not use this button.)

4

 button

Use when a ventilator (commercially-available) is 
connected. Push the button to turn on/off the 
ventilator. Turning on/off the air-conditioner also 
turns on/off the ventilator.
* No ventilator is connected if “

” appears on the 

remote controller display after pushing the 

 

button.

5

 button (Filter reset button)

Resets “  FILTER” indication after cleaning.

6

 button (Power save operation)

Use to initiate power saving mode.

7

 button

Use to select automatic swing or fixed louver 
position.
* Not available for concealed duct, slim duct, floor 

standing concealed and floor standing cabinet.

8

Operation lamp

Lights up during running.
Blinks when an error occurs or the protective device 
activates.

9

 button

Turns on the unit when pushed, and turns off when 
pushed again.

10

 button (Operation mode select button)

Selects desired operation mode.

11

 

button (Unit / Louver select button)

Selects a unit number (left) and louver number (right).

UNIT button:

If two or more indoor units are controlled by one 
remote controller, use this button to select a unit to 
adjust its air blow direction.

LOUVER button:

 (4-way cassette type 2H series only)

Selects a louver to control when adjusting the louver lock 
setting or wind direction setting separately for each louver.

12

 

button

Adjusts the set temperature.
Select the desired set point by pushing 

TEMP.

 or 

.

OPTION:

Remote controller sensor

Normally the temperature sensor of the indoor unit senses the 
temperature. The temperature around the remote controller 
can also be sensed. For details, contact your dealer.
* Do not use the function when the air conditioner is 

controlled in a group.

1 8

3

5

2

9

10

6

7

12

4

11

SWING/FIX

UNIT  LOUVER

4

Correct Usage

When you use the air conditioner for the first time or 
change the settings, follow the procedures below.
From next time, pushing the 

 button starts 

running of the air conditioner with the chosen settings.

Preparation

Turn on the power switch

• When turned on, the separation line appears and 

 blinks on the remote controller display.

* The remote controller will not work for about 1 

minute after turning on the power. This is not a 
malfunction.

REQUIREMENT

• Keep the power switch turned on during use.
• When you resume using the air conditioner after a long 

period of disuse, turn on the power switch at least 12 
hours before starting running.

Operations

1

Push the 

 

button.

The operation lamp lights up.

2

Push the “MODE 

” button to select a 

operation mode.

Each time you push the button, the operation mode 
and its icon change in the following order:

“  Dry” is not available for the concealed duct high 
static type.

3

Push the 

 button to stop running.

The operation lamp turns off.

Changing the fan speed

1

Push the “FAN 

” button to select a fan 

speed.

• Each time you push the button, fan speed and its 

indication change in the following order:
(“

 Auto” cannot be selected in the FAN mode.)

• When heating, if the room does not heat up using 

 Low”, select “

 High” or “

 Medium”.

• The temperature sensor detects the return air 

temperature at the indoor unit, which may slightly 
differ from the actual room temperature 
depending on installation condition. Set 
temperature is a target of room temperature.

• The fan speed selection function is not available 

for the concealed duct high static type. Fan speed 
is fixed and the indicator is fixed to “

 High”.

Changing the set Temperature

1

Push the “TEMP. 

 

” buttons.

Push 

 to increase the temperature, and 

 to 

decrease the temperature. (The set temperature 
cannot be changed in the fan mode.)

NOTE

When cooling

Running starts in approximately 1 minute.

When heating

• The air conditioner may continue running in the fan 

mode for about 30 seconds after stopping heating.

• The heated air comes out after a 3 to 5 minutes of 

pre-heating with the indoor fan kept turned off. (The 
pre-heat indicator 

 is displayed on the remote 

controller.)

• The fan speed becomes extremely low when the room 

temperature has reached the set temperature. 
However, for concealed duct high static types, the fan 
speed does not change after the temperature has 
reached to the set temperature.

SET

TIME

TIMER SET

TEST

FILTER

RESET

TEMP.

CL

FAN

SAVE

SWING/FIX

VENT

MODE

ON / OFF

UNIT  LOUVER

1

2

Heat

Dry

Cool

Fan

(Dehumidify)

        Low

         Medium

         High

Auto

EN-23

EN-24

2FAN_OM_DB04307201-04_EN.book  Page 12  Tuesday, December 17, 2019  6:33 PM

Summary of Contents for MCY-MHP0806HS8-E

Page 1: ...çe Nederlands Ελληνικα Svenska Suomi Norsk Dansk Românã Български Eesti Latviski Slovenèina Slovenšèina AIR CONDITIONER MULTI TYPE Owner s Manual Outdoor Unit Model name Heat Pump Model MCY MHP0806HS8 E MCY MHP1006HS8 E For commercial use 2FAN_OM_DB04307201 04_EN book Page 1 Tuesday December 17 2019 6 33 PM ...

Page 2: ... persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Contents 1 Precautions for Safety 4 2 Part Nam...

Page 3: ...owledge related to this work The qualified installer who is allowed to work at heights has been trained in matters relating to working at heights with the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such matters by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work Q...

Page 4: ... Moving parts Do not operate unit with grille removed Stop the unit before the servicing CAUTION High temperature parts You might get burned when removing this panel CAUTION Do not touch the aluminum fins of the unit Doing so may result in injury CAUTION BURST HAZARD Open the service valves before the operation otherwise there might be the burst Refrigerant recovery during operation is prohibited ...

Page 5: ...find any part of the product broken contact your dealer When transporting the air conditioner use a forklift and when moving the air conditioner by hand move the unit with 6 people Installation Only a qualified installer or qualified service person is allowed to carry out the electrical work of the air conditioner Under no circumstances must this work be done by an unqualified individual since fai...

Page 6: ... is directly exposed to the wind of air conditioner otherwise it may cause imperfect combustion When the air conditioner is operated with a combustion appliance in the same place be careful of ventilation to let fresh air enter the room Poor ventilation causes oxygen shortage When the air conditioner is used in a closed room be careful of sufficient ventilation of the room Poor ventilation causes ...

Page 7: ...ion Do not use this air conditioner for special purpose such as preserving food precision instruments art objects breeding animals car vessel etc Do not touch any switches with wet finger otherwise you may get an electric shock If the air conditioner will not be used for a considerably long time turn off the main switch or the circuit breaker for safety To make the air conditioner operate in its o...

Page 8: ...tion Symbol Description Keep dry Do not drop Do not lay down Fragile Stacking height 2 cartons can be stacked in this case Do not walk on this carton This side up Do not step Handle with care CAUTION Injury possibility Don t handle with packing band or may get injured in case of broken band 1 carton 2FAN_OM_DB04307201 04_EN book Page 7 Tuesday December 17 2019 6 33 PM ...

Page 9: ...or units Mid temperature Hot water module MMW AP LQ For details on these models read the owner s manuals that come with the indoor units 2 Part Names Outdoor unit Indoor unit 4 way cassette type Compact 4 way cassette type Air discharge Warm air comes out when cooling and cool air when heating Earth screw Equipped on the electrical control box Piping wiring panel Fixing leg Service panels Discharg...

Page 10: ...hrough here Knob Open close the return air grille Concealed duct standard type Concealed duct high static pressure type Slim duct type Ceiling type Air discharge Connect a discharge duct Air intake Air filter Electrical control box The earth screw is provided in the electrical control box Drain pan Air discharge Connect a discharge duct Air intake Air filter Electrical control box The earth screw ...

Page 11: ... attached at the site Air intake Air in the room is taken in through here Earth screw Equipped on the electrical control box Air discharge Air intake Air in the room is taken in through here Earth screw Equipped on the electrical control box Discharge louver Controls discharge air directions Metal fittings Vertical louver Automatically directs the airflow horizontally at regular intervals Drain pa...

Page 12: ...s used 12 Pre heat indicator Displayed when the heating mode is energized or defrost cycle is initiated While this indication is displayed the indoor fan stops or operate in fan mode 13 No function indicator Displayed when the function requested is not available on that model 14 Fan speed indicator Indicates the selected fan speed Auto High Medium Low 15 Louver Number display example 01 02 03 04 1...

Page 13: ...running of the air conditioner with the chosen settings Preparation Turn on the power switch When turned on the separation line appears and blinks on the remote controller display The remote controller will not work for about 1 minute after turning on the power This is not a malfunction REQUIREMENT Keep the power switch turned on during use When you resume using the air conditioner after a long pe...

Page 14: ... emitting high frequency waves Not suitable for chemical plants such as liquefied carbon dioxide refrigerant plants Do not install the air conditioner in locations where iron or other metal dust is present If iron or other metal dust adheres to or collects on the interior of the air conditioner it may spontaneously combust and start a fire A failure may occur in certain locations such as the follo...

Page 15: ... the configured settings apply to the operation Characteristics of heating Air does not come out immediately after heating starts Heated air comes out after 3 to 5 minutes depending on the room outside temperatures after the indoor heat exchanger warms up When the outside temperature increases the outdoor unit may stop While an indoor unit is running in the heating mode the outdoor unit supplies r...

Page 16: ... you push the button the indicator on the left of the remote controller changes as follows When no louver number is displayed all 4 louvers are selected SWING FIX SWING FIX SWING FIX FAN HEAT COOL DRY SWING FIX FAN HEAT operation COOL DRY operation UNIT LOUVER UNIT LOUVER No display Unit No 1 1 Unit No 1 2 Unit No 1 3 Unit No 1 4 UNIT LOUVER Unit No 1 1 Unit No 1 2 Unit No 1 3 Unit No 1 4 No displ...

Page 17: ...ted NOTE Even in louver lock mode the louver temporarily moves in the following cases When the air conditioner is stopped When heating starts When defrosting When thermo off Releasing the louver lock Set 0000 in Step 4 of Setting the louver lock The mark disappears Steps 1 3 and 5 6 of Setting the louver lock also apply to releasing the lock Adjusting the horizontal direction 1 Push and hold the a...

Page 18: ...irection to forward using a front air discharge unit sold separately CAUTION When applying a front air discharge unit to the indoor unit the 2 way air discharge function forward downward is not available Such use may lower the air temperature and cause water leakage For details on the installation read the installation manual that comes with a front air discharge unit sold separately When using a ...

Page 19: ... unit by selecting them individually To set louver direction individually push the button left side of the button to display an indoor unit number in the control group Then set the louver direction of the displayed indoor unit When no indoor unit number is displayed all indoor units in the control group can be controlled simultaneously Each time you push the left side of the button the indication ...

Page 20: ...ositions 5 Be sure to tighten the air discharge with the removed fixing screws so that it does not come off 9 Tips for Saving Energy and Comfortable Performance To save energy and perform comfortable cooling and heating Clean the air filter often A clogged air filter lowers the cooling heating performance Do not cool heat too much WARNING Do not expose your body to cool air directly for a long tim...

Page 21: ...ning make sure to ask the qualified service person particularly following models 4 way cassette type Compact 4 way cassette type 2 way cassette type 1 way cassette type Ceiling type Concealed duct standard type Concealed duct high static type Slim duct type Floor standing type CAUTION Do not push buttons with wet hands Doing so may result in electric shock Cleaning the air filters When the filter ...

Page 22: ... day or so to dry the inside Turn off the main power switch Clean the air filter and then attach it Periodic inspection After being used for a long period of time the parts may deteriorate or malfunction or the drainage may worsen due to heat moisture dust or general usage In addition to the maintenance it is recommended that you have a inspection charges apply performed by the dealer where you pu...

Page 23: ...s the timer ON or OFF Does not operate Is it a power failure Is the power switch turned off Is the power fuse or breaker blown Has the protective device operated The operation lamp goes on Is the timer ON The operation lamp goes on Are COOL or FAN and HEAT selected simultaneously indication is lit on the display of the remote controller Is outdoor temperature out of operation temperature range Air...

Page 24: ...cate CODE No 01 latest to 04 oldest CAUTION Do not push button because all the trouble history of the indoor unit will be deleted 3 After confirmation push button to return to the usual display Model Sound pressure level dBA Weight kg Cooling Heating MCY MHP0806HS8 E 58 59 147 MCY MHP1006HS8 E 59 60 147 Declaration of Conformity NOTE This declaration becomes invalid if technical or operational mod...

Page 25: ...DHV2307201 00 2FAN_OM_DB04307201 04_EN book Page 24 Tuesday December 17 2019 6 33 PM ...