background image

– 3 –

• When the air conditioner is used in a closed room, be careful of sufficient ventilation of the room. Poor ventilation 

causes oxygen shortage.

• Do not expose your body to cool air directly for a long time and do not cool yourself excessively.

Doing so may result in deteriorated physical condition and ill health.

• Never insert your finger or a stick into the air intake or discharge.

Doing so may result injury as the fan is rotating at high speed inside the unit. 

• Consult the shop where you purchased the air conditioner if air conditioning (cooling and heating) is not performed 

properly as a refrigerant leakage may be the cause. Confirm the repair details with a qualified service person (*1) 
when the repair includes additional charging of the refrigerant. 

• Be sure to stop running the air conditioner and turn off the breaker before cleaning.

Otherwise, injury may result as the fan is rotating at high speed inside the unit.

Repairs

• When you have noticed that some kind of error (such as when an error display has appeared, there is a smell of burning, 

abnormal sounds are heard, the air conditioner fails to cool or heat or water is leaking) has occurred in the air conditioner, 
do not touch the air conditioner yourself but set the circuit breaker to the OFF position, and contact a qualified service 
person. Take steps to ensure that the power will not be turned on (by marking “out of service” near the circuit breaker, for 
instance) until qualified service person arrives. Continuing to use the air conditioner in the error status may cause 
mechanical problems to escalate or result in electric shocks, etc.

• If you have discovered that the fan grille is damaged, do not approach the outdoor unit but set the circuit breaker to the OFF 

position, and contact a qualified service person to have the repairs done. Do not set the circuit breaker to the ON position 
until the repairs are completed.

• If you have discovered that there is a danger of the indoor unit’s falling, do not approach the indoor unit but set the circuit 

breaker to the OFF position, and contact a qualified installer or a qualified service person to refit the unit. Do not set the 
circuit breaker to the ON position until the unit has been refitted.

• If you have discovered that there is a danger of the outdoor unit’s toppling over, do not approach the outdoor unit but set 

the circuit breaker to the OFF position, and contact a qualified installer or a qualified service person to have the 
improvements or refitting done. Do not set the circuit breaker to the ON position until the improvements or refitting is 
completed.

• Do not customize the unit. Doing so may result in fire, electric shock, etc.

Relocation

• When the air conditioner is to be relocated, do not relocate it yourself but contact a qualified installer or a qualified service 

person. Failure to relocate the air conditioner properly may result in electric shocks and / or a fire.

CAUTION

To disconnect the appliance form the main supply

• This appliance must be connected to the mains by means of a switch with a contact separation of at least 

3 mm

.

Installation fuse (all types can be used) must be used for the power supply line of this air conditioner.

Installation

• Certainly lay the drain hose for perfect draining. Bad drainage may cause flooding in the house and getting 

furniture wet.

• Make sure to connect the air conditioner to an exclusive power supply of the rated voltage, otherwise the unit 

may break down or cause a fire.

• Confirm that the outdoor unit are fixed on the base. Otherwise, falling down of the units or other accidents may 

occur.

Operation

• Do not use this air conditioner for special purpose such as preserving food, precision instruments, art objects, 

breeding animals, car, vessel, etc.

• Do not touch any switches with wet finger, otherwise you may get an electric shock.
• If the air conditioner will not be used for a considerably long time, turn off the main switch or the circuit breaker, 

for safety.

• To make the air conditioner operate in its original performance, operate it within the range of the operating 

temperature specified in the instructions. Otherwise it may cause a malfunction, or water leak from the unit.

• Prevent any liquid from falling into the remote controller. Do not spill juice, water or any kind of liquid.
• Do not wash the air conditioner. Doing so may result in electric shock.

• Check whether the installation base and other equipment have become deteriorated after being used for a long 

time. Leaving them such condition may result in the unit’s falling down and causing injury. 

• Do not leave flammable sprays or other flammable materials near the air conditioner, and do not spray flammable 

aerosol directly to the air conditioner. They may catch fire.

• Be sure to stop running the air conditioner and turn off the breaker before cleaning.

Otherwise, injury may result as the fan is rotating at high speed inside the unit.

• Ask for cleaning of the air conditioner to be performed by the dealer.

Cleaning the air conditioner in an improper manner may cause damage to plastic parts, insulation failure of 
electric parts, etc. and result in a malfunction. In the worst case, it may result in water leakage, electric shock, 
smoke emission and fire.

• Do not put a water container such as a vase on the unit.

Water intrusion into the unit may occur and it may cause deterioration of electric insulation and result in electric 
shock.

(*1) Refer to the “Definition of Qualified Installer or Qualified Service Person.”

„

Information on the transportation, handling and storage of the 
carton

Examples of indication on the carton

Symbol

Description

Symbol

Description

Symbol

Description

Keep dry

Do not drop

Do not lay down

Fragile

Stacking height 
(12 cartons can 
be stacked in 
this case)

Do not walk on 
this carton

This side up

Do not step

Handle with 
care

CAUTION

Injury possibility.
Don’t handle with packing band, or may get injured in case of 
broken band.

Stacking notice.

In case that cardboard boxes protrude out of pallet when 
stacking.
Lay a 10 mm thick plywood over the pallet.

11 cartons

5-EN

6-EN

Summary of Contents for MCY-MAP0401HT2DZ

Page 1: ...MCY MAP0401HT MCY MAP0501HT MCY MAP0601HT MCY MAP0401HTZ MCY MAP0501HTZ MCY MAP0601HTZ MCY MAP0401HTZG MCY MAP0501HTZG MCY MAP0601HTZG For commercial use MCY MAP0401HT2D MCY MAP0501HT2D MCY MAP0601HT2D MCY MAP0401HT2DZ MCY MAP0501HT2DZ MCY MAP0601HT2DZ MCY MAP0401HT2DZG MCY MAP0501HT2DZG MCY MAP0601HT2DZG ...

Page 2: ...edge related to this work The qualified installer who is allowed to do the refrigerant handling and piping work involved in installation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to refrigerant handling and piping work on the...

Page 3: ... installation work has been completed have the installer explain about the circuit breaker positions In the event that error has occurred in the air conditioner set the circuit breaker to the OFF position and contact a service person If you install the unit in a small room take appropriate measures to prevent the refrigerant from exceeding the limit concentration even if it leaks Consult the deale...

Page 4: ...isconnect the appliance form the main supply This appliance must be connected to the mains by means of a switch with a contact separation of at least 3 mm Installation fuse all types can be used must be used for the power supply line of this air conditioner Installation Certainly lay the drain hose for perfect draining Bad drainage may cause flooding in the house and getting furniture wet Make sur...

Page 5: ...models read the owner s manuals that come with the indoor units 2 Part names Outdoor unit Indoor unit 4 Way Cassette Type Compact 4 Way cassette Type Air intake They are provided at rear and left sides Fixing leg Equipped on the electrical control box Air discharge Hot air is discharged when cooling operation is performed Cold air is discharged when heating operation is performed Power source hole...

Page 6: ... Air in the room is taken in through here Concealed Duct Standard Type Concealed Duct High Static Pressure Type Slim Duct Type Ceiling Type Air filter Filters out dust Inside the return air grille Air discharge The air discharge duct is connected Earth screw Equipped on the electrical control box Return air grille Air in the room is taken in through here Earth screw Equipped on the electrical cont...

Page 7: ...o 8 indoor units Display section All indicators are displayed in the display example below Actually only the selected options will be displayed blinks on the display of the remote controller the first time the power switch is turned on The initial settings progress while is blinking Start to use the remote controller after has disappeared NOTE The LCD may temporarily be blurred due to static elect...

Page 8: ...tton is pushed while operation mode is fixed to cool or heat by the air conditioner administrator 20 Operation ready display This display appears on some models 21 Service display Displayed while the protective device works or a trouble occurs 2 14 15 5 7 3 1 4 6 11 9 8 13 12 10 18 17 19 20 21 16 Auto High Medium Low Operation section Once the settings have been configured all you need to do is pu...

Page 9: ...or about 1 minute after turning on the power This is not a malfunction REQUIREMENT Keep the power switch turned on during use When you resume using the air conditioner after a long period of disuse turn on the power switch at least 12 hours before starting running Operations 1 Push the button The operation lamp lights up 2 Push the MODE button to select a operation mode Each time you push the butt...

Page 10: ...ode and indication change in the following order and the time indicator blink 2 Push the buttons to set the period of time until the timer actions The time setting increases in 0 5 hour 30 minute increments each time you push The setting increases in 1 hour increments if it is over 1d 24 hours The maximum is 7d 168 hours On the remote controller settings between 0 5h and 23 5h 1 are displayed as i...

Page 11: ... air or noise coming from the air discharge of the outdoor unit 7 Notes on operations and performance Check before operation Turn on the power switch at least 12 hours before starting operation Make sure the earth wire is securely connected Make sure the air filter is attached to the indoor unit Heating performance A heat pump system which gathers outside heat and emits it into a room is used for ...

Page 12: ...istics of air Cool air falls and warm air rises CAUTION Point the louver horizontally during cooling If pointing downward for cooling dew may form on the surface of the air discharge or louver and may drop down NOTE If pointing horizontally for cooling dew may form on the surface of the cabinet or louver and may drop down If pointing horizontally for heating the room temperature may be uneven Do n...

Page 13: ...ions below may sometimes be displayed and may not set the louver to the highest position Indications when swinging is stopped Indications when swinging is stopped SWING FIX SWING FIX SWING FIX FAN HEAT COOL DRY SWING FIX FAN HEAT operation COOL DRY operation UNIT LOUVER UNIT LOUVER Unit No 1 4 No display Unit No 1 1 Unit No 1 2 Unit No 1 3 UNIT LOUVER No display Unit No 1 1 Unit No 1 2 Unit No 1 3...

Page 14: ...wing figure is selected NOTE Even in louver lock mode the louver temporarily moves in the following cases When the air conditioner is stopped When heating starts When defrosting When thermo off Releasing the louver lock Set 0000 in Step 4 of Setting the louver lock The mark disappears Steps 1 3 and 5 6 of Setting the louver lock also apply to releasing the lock Adjusting the horizontal direction 1...

Page 15: ...et the air discharge direction to forward using a front air discharge unit sold separately CAUTION When applying a front air discharge unit to the indoor unit the 2 way air discharge function forward downward is not available Such use may lower the air temperature and cause water leakage For details on the installation read the installation manual that comes with a front air discharge unit sold se...

Page 16: ...ion changes as follows When cooling Point the louver horizontally to send cool air across the entire room When heating Point the louver downward to send heated air to the floor When adjusting louver direction horizontally point the vertical grille inside the horizontal louver in your preferred direction SWING FIX SWING FIX 1 2 SET TIME TIMER SET TEST FILTER L L RESET TEMP CL FAN SAVE A A SWING FIX...

Page 17: ...ir conditioner under the following temperature conditions If air conditioner is used outside of the above conditions safety protection may operate Clean the air filter often A clogged air filter lowers the cooling heating performance Do not cool heat too much WARNING Do not expose your body to cool air directly for a long time and do not cool yourself excessively Doing so may result in deteriorate...

Page 18: ... pull it toward you to remove it 2 Take out the air filter inside the return air grille 3 Vacuum dust or brush clean If heavily stained it is more effective to wash in lukewarm water mixed with neutral detergent After washing rinse it well and dry it in the shade Reinstall the cleaned air filter Floor Standing Concealed Type 1 Push down hook of the air filter on the front panel Lower side 2 Pull t...

Page 19: ...eard and the operation sound may become larger for 2 or 3 minutes immediately after the operation has started They are flowing sound of refrigerant or draining sound of dehumidifier Slight clacking sound is heard This is sound generated when heat exchanger etc expand and contract slightly due to change of temperature Discharge air smells Various smell such as one of wall carpet clothes cigarette o...

Page 20: ...to the following Confirmation of error history for confirmation When a trouble occurred on the air conditioner the trouble history can be confirmed with the following procedure The trouble history is stored in memory up to 4 troubles The history can be confirmed from both operating status and stop status Procedure Description 1 When pushing and buttons at the same time for 4 seconds or more the fo...

Page 21: ...te PLYMOUTH Devon PL6 7DB United Kingdom Hereby declares that the machinery described below Generic Denomination Air Conditioner Model type Heat Pump Model MCY MAP0401HT MCY MAP0501HT MCY MAP0601HT MCY MAP0401HTZ MCY MAP0501HTZ MCY MAP0601HTZ MCY MAP0401HTZG MCY MAP0501HTZG MCY MAP0601HTZG Commercial name MINI Super Modular Multi System Air Conditioner MINI SMMS series Complies with the provisions...

Page 22: ... 21 MEMO ...

Page 23: ... 22 MEMO ...

Page 24: ... manufacturer TOSHIBA CARRIER CORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom ...

Reviews: