Connecting Hardware Devices
Cooling fans
54
2
Remove the screw securing the intake fan module in place, then slide the module
from the chassis.
Removing the intake fan module
3
Reinstall the access panel, reconnect all signal and power cables, then turn on the
server. For instructions, read Steps 6 through 9 in
Maintenance overview
on page
50.
Installing an intake fan
1
If the server is in operation, shut it down. Then remove the access panel. For
detailed instructions, read Steps 1 through 4 in
Maintenance overview
on page 50.
2
If installing a redundant fan, remove the screw securing the cover plate to the fan
bay, then remove the cover plate (there is no cover plate when installing a
replacement fan).
Removing the fan cover plate (redundant fan only)
3
Position the intake fan module in the fan bay and replace the screw to hold it in
position.
Installing a cooling fan while the server is on could result in electric shock and
shorten the service life of both the fan and the server.