Line Lock V PHASE CONTROL
■
LINE LOCK PHASE
When a video switcher switches two or more cameras, the picture may fluctuate on the video
monitor due to the different AC line phase of each camera. In this case, adjust the V PHASE
controller to get a stable image.
NOTE
●
The camera is synchronized to the power frequency of 60
±
1 Hz covering a normal
fluctuation of the power frequency. However, the camera may not cover a large
fluctuation caused from the power generated by an engine generator, etc.
●
It takes about 10 seconds or more until a stable synchronization is obtained after the
power is turned on. This is normal, because several seconds are required to stabilize
the camera against power noise.