EJL-136F
8
Unit: inch(mm)
3.46(88)
1.57(40)
4.96(126)
1.38(35)
3.58(91)
R(PT)½ Male Screw (Two places)
(L
2
)
Φ
2
.6
0
(
Φ
6
6
)
3.43(87)
L1
Note1: Cable glands are not provided for LF414 of FM and
CSA approved type.
Refer to the part Cable connection port at detector.
Note2: 1 inch = 25.4mm
ASME B 16.5 class 150 and class300 dimensions:
Meter size
(inch)
L1
(inch)
L2
(inch)
D1
(inch)
Weight
(lb)
1
3.15
6.61
2.60
approx. 7
EN 1092-1 PN16 and JIS B 2220 10K dimensions:
Meter size
(mm)
L1
(mm)
L2
(mm)
D1
(mm)
Weight
(kg)
25
80
168
66
approx. 3
The dimension of L1 changes when the material of
grounding ring is chosen Pt-Ir or Ta
Meter size
L1
1/2”(15mm)
3.03 inch(77mm)
1”(25mm)
3.74 inch(95mm)
1 1/2”(40mm)
4.53 inch(115mm)
2”(50mm)
4.96 inch(126mm)
3”(80mm)
4.96 inch(126mm)
4”(100mm)
5.35 inch(136mm)
Figure 7. Separate type detectors LF410/LF414
Meter sizes 1" (25mm)