DP-1910F
022
SIG. INTERVAL
1 = 100 ms
2 = 200 ms
3 = 500 ms
Selects the time interval between the receiving signal
and the transmitting signal.
023
TCF CHECK
1 = Normal (Short)
2 = Long
Selects the TCF check interval Long/Short
024
CED FREQ.
1 = 1080 Hz (non ITU-T)
2 = 2100 Hz
Selects the CED frequency 2100/1080 Hz
025
COMM. START-
UP
1 = First
2 = Second
Selects the communication start-up condition (XMT
and Polling).
(Used when Echo Suppression is disabled.)
026
NON-
STANDARD
1 = Off (Invalid)
2 = On (Valid)
Selects own mode.
027
SHORT
PROTOCOL B
1 = Off (Invalid)
2 = On (Valid)
Selects the short protocol mode.
028
SHORT
PROTOCOL D
1 = Off (Invalid)
2 = On (Valid)
Selects the short protocol mode. When activated, it
allows the machine to automatically store the modem
speed for each Auto Dial Number.
029
REMOTE DIAG.
1 = Off (will not accept)
2 = On (accepts)
Selects whether the machine accepts Remote
Diagnostics from the service station.
030
CED & 300 bps
1 = 75 ms
2 = 1 sec
Selects the pause interval between the CED and the
300 bps signal.
(Used when Echo Suppression is disabled.)
031
RTC = EOL x 12
1 = Off (EOLx6)
2 = On (EOLx12)
Selects the RTC signal, EOLx6 or EOLx12.
032
V34 TX START
2400-33600bps
Selects the transmission modem start speed for V.34
communication, 33600-2400 bps.
(Press the
“
”
,
“
”
keys to select the symbol rate.)
033
V34 RX START
2400-33600bps
Selects the receiving modem start speed for V.34
communication, 33600-2400 bps.
(Press the
“
”
,
“
”
keys to select the symbol rate.)
034
V34 TX SR
2400-3429sr
Selects the transmission symbol rate for V.34, 3429/
3200/3000/2800/2400 sr.
(Press the
“
”
,
“
”
keys to select the symbol rate.)
035
V34 RX SR
2400-3429sr
Selects receiving symbol rate for V.34, 3429/3200/
3000/2800/2400 sr.
(Press the
“
”
,
“
”
keys to select the symbol rate.)
036
Not Used
037
PROTOCOL
DISDPLAY
1 = Off (not displayed)
2 = On (displayed)
Selects whether to display the modem speed during
communication.
(Press the Job Status Key to display)
038
Not Used
039
FLASH TIME
5 = 50 ms
~
100 = 1000 ms
Selects the pause interval before activating the Flash
key.
040
FLASH TIME
(PSTN)
5 = 50 ms
~
100 = 1000 ms
Selects the pause interval before activating the Flash
key.
(For Germany, Austria and Czech)
041
PAUSE TIME
1 = 1 sec.
~
10 = 10 sec.
Selects the pause interval from 1 sec. ~ 10 sec. for
dialing through a switchboard or for international
calls.
042
Not Used
Function Parameter Table
No.
Parameter
Selections
Function