e-STUDIO182/212/242
© 2009 TOSHIBA TEC CORPORATION All rights reserved
DRUM RELATED SECTION
10 - 22
10.7.18 Toner cartridge interface PC board (CTIF)
(1) Take off the process unit.
P.10-9 "10.7.1 Process unit"
(2) Take off the inner tray.
P.2-18 "2.5.2 Inner tray"
(3) Disconnect 1 connector, remove 1 screw and
then take off the toner cartridge interface PC
board.
Fig. 10-43
Connector
Toner cartridge
interface PC board