12.6 Disassembly and Replacement
Note:
When disassembling the fuser unit or replacing any parts in it, be sure that the wire harness is
correctly set, and also be careful not to catch it between other parts.
a. Make sure that the terminal of the thermostat harness does not contact the metal plate.
b. Route the harness of the thermostat so that it is hooked on the notches of the rib.
c. Route the harnesses of the thermistor so that they are hooked on the housing as shown below.
d. Route the harnesses of the thermistor so that they are hooked on the housing as shown below.
Fig. 12-6
a
c
b
d