e-STUDIO182/212/242
© 2009 TOSHIBA TEC CORPORATION All rights reserved
DRUM RELATED SECTION
10 - 18
10.7.14 Transfer unit
Note:
When taking off the transfer unit, take off the process unit first to prevent the drum from light.
(1) Open off the ADU cover.
(2) Take off 2 guides.
Fig. 10-31
(3) Take off the transfer unit while pulling the
lever.
Fig. 10-32
(4) Remove 1 screw and take off the harness
cover.
Fig. 10-33
Guide
Transfer unit
Screw
Harness cover