6
© 2009 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO182/212/242
SCANNER
6 - 7
Description of input signal
Clock input
SCNCLK
Input
The scan motor is rotated by inputting the pulses (CLK).
*
Internal circuit of the motor driver works when the first
pulse of the input becomes ON.
*
The maximum input clock is 9000 PPS.
Motor rotation direction setting SCNDIR
Input
The direction of the motor rotation is determined by setting
the level of the signal.
“H”: Clockwise direction
“L”: Counterclockwise direction
*
The rotation direction within 7 µsec. before the first
pulse of the CLK comes should not be changed ON
and after the last pulse goes OFF.
Cutting off of the drive output
SCNEN
Input
Forcibly turn ON/OFF the excitation drive.
“H”: Normal operation (Excited)
“L”: Excitation drive is forcibly shut off (Not excited)
Excitation mode Setting-1
SCNMD0
Input
Sets the excitation mode.
*
The setting should not be changed within 7µsec. after
the first pulse of the CLK comes ON.
Resetting
SCANRST Input
Resets the whole system.
“L” (10 µsec. or more): Internal circuit of the driver is
initialized.
*
The motor drive circuit is automatically reset when the
power is turned ON.
Voltage to set value for the
motor current
SCNNVR
Input
Sets the reference current value for the constant current
detection.
Motor wire current value can be set in the range of 0 to 2.0
(A)/phase by applying the analog voltage of 0 to 5 (V).
Summary of Contents for e-studio182
Page 12: ......
Page 18: ...e STUDIO182 212 242 2009 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 6 ...
Page 76: ...e STUDIO182 212 242 2009 TOSHIBA TEC CORPORATION All rights reserved COPY PROCESS 3 14 ...
Page 120: ...e STUDIO182 212 242 2009 TOSHIBA TEC CORPORATION All rights reserved SCANNER 6 26 ...
Page 128: ...e STUDIO182 212 242 2009 TOSHIBA TEC CORPORATION All rights reserved LASER OPTICAL UNIT 7 8 ...
Page 228: ...e STUDIO182 212 242 2009 TOSHIBA TEC CORPORATION All rights reserved FUSER EXIT UNIT 12 24 ...
Page 257: ......
Page 258: ......