13
© February 2007 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO166/206
FUSER / EXIT UNIT
13 - 7
4) Temperature control at Energy Saving Mode
This equipment has the following two types of temperature control for saving energy and returns to
ready status to perform printing in each mode upon printing request.
The period of time from the printing request to this mode can be set in Setting Mode (08).
Auto Power Save Mode (08-205):
When the printing is not performed in a specified period of time (default: 15 min.) after the previous
printing is completed, the equipment enters to Auto Power Save Mode to turn OFF the heater lamp.
*
When a value other than OFF is set for the “Fuser roller temperature in Auto Power Save Mode
(code 08-409/448)”, the equipment controls to maintain the fuser roller temperature at the preset
value by turning the 2 heater lamps ON/OFF alternately.
Auto Shut Off Mode (08-206):
When no operation is performed in a specified period of time (default: 15 min.) after the equipment
entered to Auto Power Save Mode, the equipment then enters Auto Shut Off Mode to be in the OFF
state (e.g. turns off the unnecessary displays on the control panel, etc.).
Fig. 13-4
Warming-up
Ready
During printing
Fixed time(08-205)
Fixed time(08-206)
Auto Power Save Mode
(Heater lamp OFF)
Auto
Shut Off
Mode
°C
170
0
Temperature
of fuser roller
Heater lamp
ON
OFF
Summary of Contents for e-STUDIO 206
Page 6: ......
Page 10: ...e STUDIO166 206 February 2007 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 4 ...
Page 68: ...e STUDIO166 206 February 2007 TOSHIBA TEC CORPORATION All rights reserved COPY PROCESS 3 14 ...
Page 88: ...e STUDIO166 206 February 2007 TOSHIBA TEC CORPORATION All rights reserved CONTROL PANEL 5 8 ...
Page 132: ...e STUDIO166 206 February 2007 TOSHIBA TEC CORPORATION All rights reserved DRIVE UNIT 9 10 ...
Page 236: ...e STUDIO166 206 February 2007 TOSHIBA TEC CORPORATION All rights reserved PC BOARDS 15 4 ...
Page 237: ......
Page 238: ......