e-STUDIO166/206
SCANNER
6 - 17
(3)
Remove the seal which fixes the harness.
Note:
Attach the seal by following the procedure
below.
-
Place the flat harness along the edge
of the scanner base.
-
Align the seal with the two edges of
the scanner base.
Fig. 6-22
(4)
Lift up the CIS unit, disconnect 1 connector
on the bottom of the CIS unit, and then take
off the CIS unit.
Notes:
•
Take care not to contaminate the CIS unit
surface with fingerprints, dust or such.
•
Be sure to perform "05-310" with the
platen cover or the ADF closed after
replacing the CIS unit.
Fig. 6-23
(5)
Release 2 latches each to take off 2 original
glass guides from the CIS unit.
Fig. 6-24
Seal
Harness
CIS unit
Connector
Original glass guide