6
© February 2007 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO166/206
SCANNER
6 - 15
[D] CIS home position sensor (S1)
[E]
Platen sensor (S2)
(1)
Take off the original glass.
"
P.6-12 "[A] Original glass"
(2)
Remove 1 screw and take off the CIS home
position sensor with the bracket.
Fig. 6-16
(3)
Release 2 latches, take off the CIS home
position sensor, release the harness from
harness clamp and disconnect 1 connector.
Fig. 6-17
(1)
Take off the scanner top cover.
"
P.6-13 "[B] Scanner top cover"
(2)
Remove 1 screw and take off the sensor with
the bracket.
(3)
Disconnect 1 harness clamp and 1 connec-
tor.
Fig. 6-18
Bracket
CIS home position sensor
CIS home position sensor
Connector
Bracket
Connector