29597AA
47
NETWORK SETUP
Network Setup allows the user to adjust settings such as Ports, setup emergency PPP information for use with the Emergency Agent
and enable Remote Access.
Time Out Value
When attempting to connect to the DVR, if the connection does not succeed during the timeout
period (seconds), the connection will be terminated.
Emergency Port
Used to connect to the Alarm Monitor software.
Center Port
Used to connect to the Surveillix remote software. This port must be specified in the Remote
Software to connect to the DVR.
Note
Center Port 1025 is not available for remote connections. It is used by the ATI VGA management suite
Image Port
Used to transfer the video to the Surveillix remote software.
Search Port
Used to transfer search information to the Surveillix remote software.
Note
If connecting to the DVR through a firewall, the above ports must be open to incoming and outgoing traffic.
Resolution
By setting the resolution low, the images will be sent faster, however, the image quality will be
reduced considerably. When set to Original, full quality video will be sent [720 x 480 (NTSC) 720 x
576 (PAL)]. The Original setting is very bandwidth intensive.
Transport Rate
Throttles the bandwidth on the DVR. This option is based on percentages of images sent.
Use with
Emergency Agent
Enable RS-232
Keyboards (PTZ)
Between DVR and Remote Client
Settings for Video Sent to Remote Client
Use with Remote
Connections
Summary of Contents for DVS32-240-2T
Page 2: ...ii ...
Page 4: ...iv ...
Page 10: ...x NOTES ...
Page 18: ...18 NOTES ...
Page 70: ...70 NOTES ...
Page 84: ...84 NOTES ...
Page 87: ...29597AA 87 LDAP INTEGRATION This chapter includes the following information Installing LDAP ...
Page 90: ...90 NOTES ...
Page 94: ...94 ...