CMOD/FMOD Control
https://www.toshiba.com/tic/
33
Command Mode and
Frequency Mode Control
Command control includes instructions such as
Stop, Run, Jog, etc. The source of the Command
signal must be established for normal operation.
Frequency commands control the output speed of
the Q9 Plus ASD. The source of the frequency
(speed) control signal must be established for
normal operation.
The command and speed reference may come from
either internal or external sources
. Once the signal
source is selected for either function, the system
may be configured to use the selected signal all of
the time or switch under user-defined conditions.
Command and Frequency control may be carried
out using any one of several control methods
(signal sources) or combinations. In the event that
multiple control commands are received, only the
user-configured signal source is recognized. The
primary control method for command and
frequency control are selected at
command and frequency control sources and the
system throughput applicables.
Command Control
The Command Mode selection of
the primary command source of the ASD when
operating in the Remote mode. While operating in
the Local mode the EOI is the command source.
Placing the EOI in the Local mode selects the EOI
Keypad as the Command Mode source. Local
mode operation may be superseded by other
settings.
Example:
With the EOI set to Local, an activated
discrete input terminal set to Serial/Local Switch
places the system in the Remote mode and the
settings of
control.
Once the discrete input terminal is no longer
activated the system will return to the command of
the EOI and run at the commanded EOI value.
The source of the Command
control signal may be
selected by:
setting,
• Via communications, or
• Placing the EOI in the Local mode.
Possible Command signal source selections
include the following (
):
• Terminal Board (default setting),
• EOI Keypad,
• RS485/BACnet, or
• Communication Option Board.
Note:
See
for the
available discrete input terminal
functions that may be used to change
the active control source (i.e., Serial/
Local Switch, V/I Terminal Priority,
etc.).
Frequency Control
The
Frequency Mode 1 (or Frequency Mode 2)
setting establishes the primary source of the
frequency-control input for the Q9 Plus ASD.
Frequency Mode 1 is used for speed control unless
the Reference Priority Selection parameter is
configured to switch this setting under user-defined
conditions (see
).
shows the relationship
between the frequency-control sources. As
indicated in the figure, other items may supersede
the selection at
Placing the EOI in the Local mode selects EOI
Keypad as the frequency source. Operating in Local
mode may be superseded by other settings.
Example:
With the EOI as the frequency-control
source because the Local/Remote setting is set to
Local, activating a discrete input terminal that is set
to
V/I Terminal Priority enables the V/I terminal as
the frequency-control source for the duration of the
activation.
The source of the frequency
control signal may be
selected by:
setting,
• Via communications, or
• Placing the EOI in the Local mode.
WARNING
Summary of Contents for DN-68249-003
Page 1: ...ADJUSTABLE SPEED DRIVES Q9 DN 68249 003 INSTALLATION OPERATION MANUAL April 2020 ...
Page 2: ......
Page 3: ...Document Number 68249 003 April 2020 Q9 Plus ASD Installation Operation Manual ...
Page 4: ......
Page 12: ...Table of Contents Q9 Plus ASD Install Op Manual iv https www toshiba com tic ...
Page 305: ......