System Operation
https://www.toshiba.com/tic/
29
Default Setting Changes
To change a default parameter setting, go to the
root of the Program menu and turn the Rotary
Encoder until the desired parameter group is within
the cursor block. Press the Rotary Encoder (repeat
if there is a submenu).
Press the Rotary Encoder to select the default
setting to be changed. The selection takes on the
reverse video format (dark background, light text).
Turn the Rotary Encoder to change the value of the
parameter. To exit the menu without saving the
change, press the ESC key. To save the new
setting, press the Rotary Encoder.
Note:
Some parameters (e.g.,
,
, etc.) require that the ASD be
Reset or powered off and then on
again in order to enable the new
setting.
For a complete listing of the Program menu items,
see the section titled
. The menu items are mapped
for convenience, and Direct Access Numbers are
listed where applicable. From any menu, press the
Mode key to return to the root menu. Repeated
Mode key entries loop the system through the root
menus as shown in
The default settings may also be changed by
entering the Parameter Number of the setting to be
changed at the Direct Access menu (Program
Direct Access
applicable parameter number). A
listing of the Direct Access/Parameter Numbers and
a description of the associated parameter may be
.
Search For Default Setting Changes
A listing of all parameters that have been changed
from the factory default settings may be viewed
sequentially by accessing the Changed From
Default
screen (Program
Utilities
Changed
From Default
)
.
The Changed From Default
feature allows the user
to view (and/or change) the parameters that are
different from the factory default or post-reset
settings. Once the Changed From Default screen is
displayed, the system automatically scrolls through
all of the system parameters and halts once
reaching a changed parameter.
The Rotary Encoder
may be clicked once clockwise
to continue scrolling forward or clicked once
counterclockwise to begin scrolling in reverse. With
each click of the Rotary Encoder from a stop, the
system scrolls and stops at the next parameter that
has been changed.
Pressing the Rotary Encoder
while a changed
parameter is displayed accesses the settings of the
changed parameter for viewing or changing.
Pressing ESC while the system is performing a
Changed From Default search terminates the
search. Pressing ESC when done searching (or
halted at a changed parameter) returns the system
to the Program Menu.
Pressing the Mode key when finished searching or
when halted at a changed parameter returns the
system to the
primary menu loop.
Summary of Contents for DN-68249-003
Page 1: ...ADJUSTABLE SPEED DRIVES Q9 DN 68249 003 INSTALLATION OPERATION MANUAL April 2020 ...
Page 2: ......
Page 3: ...Document Number 68249 003 April 2020 Q9 Plus ASD Installation Operation Manual ...
Page 4: ......
Page 12: ...Table of Contents Q9 Plus ASD Install Op Manual iv https www toshiba com tic ...
Page 305: ......