E6581737
- 26 -
c001
-
c006
setup value
c021
-
c026
setup value
0: No action
1:
fa06
(Communication command 1)
2:
fa23
(Communication command 2)
3:
fa07
(Frequency command, 0.01Hz)
5:
fa50
(Terminal output data)
6:
fa51
(FM analog output)
8:
f601
(Stall prevention level, %)
13:
acc
(Acceleration time 1, 0.1s)*
14:
dec
(Deceleration time 1, 0.1s)*
15:
ul
(Upper limit, 0.01Hz)
16:
vb
(Torque boost value 1, 0.1%)
17:
vlv
(Base frequency voltage 1, 0.1V)
0: No action
1:
fd01
(Status information 1)
2:
fd00
(Output frequency, 0.01Hz)
3:
fd03
(Output current, 0.01%)
4:
fd05
(Output voltage, 0.01%)
5:
fc91
(Alarm information)
6:
fd22
(PID feedback value, 0.01Hz)
7:
fd06
(Input terminal board status)
8:
fd07
(Output terminal status)
9:
fe36
(VIB input, 0.01%)
10:
fe35
(VIA input, 0.01%)
11:
fe37
(VIC input, 0.01%)
12:
fd04
(Input voltage (DC detection), 0.01%)
13:
fd16
(Estimated speed (real-time value), 0.01Hz)
14:
fd18
(Torque, 0.01%)
19:
f880
(Free notes)
20:
fd29
(Input power, 0.01kW)
21:
fd30
(Output power, 0.01kW)
22:
fe14
(Cumulative operation time, hour)
23:
fe40
(FM terminal output monitor, 0.01%)
25:
fd20
(Torque current, 0.01%)
26:
fd23
(Motor overload factor, 0.01%)
27:
fd24
(Drive overload factor, 0.01%)
28:
fd25
(PBR overload factor, %)
29:
fd26
(Motor load factor, %)
30:
fd27
(Drive load factor, %)
31:
fe56
(Pulse train input, pps)
32:
fe70
(Drive rated current, 0.1A)
33:
fe76
(Input Watt-hour, 0.1kWh
10
f749
)
34:
fe77
(Output Watt-hour, 0.1kWh
10
f749
)
35:
fd83
(IGBT temperature, degree C)
*1 The unit of
acc
,
dec
is according to the parameter
f519
.
*2 The unit of
fe76
,
fe77
is according to the parameter
f749
.