1-3-1
DVDN_ISPT
IMPORTANT SAFETY PRECAUTIONS
Product Safety Notice
Some electrical and mechanical parts have special
safety-related characteristics which are often not
evident from visual inspection, nor can the protection
they give necessarily be obtained by replacing them
with components rated for higher voltage, wattage,
etc. Parts that have special safety characteristics are
identified by a
!
on schematics and in parts lists. Use
of a substitute replacement that does not have the
same safety characteristics as the recommended
replacement part might create shock, fire, and/or other
hazards. The Product’s Safety is under review
continuously and new instructions are issued
whenever appropriate. Prior to shipment from the
factory, our products are carefully inspected to confirm
with the recognized product safety and electrical
codes of the countries in which they are to be sold.
However, in order to maintain such compliance, it is
equally important to implement the following
precautions when a set is being serviced.
Precautions during Servicing
A.
Parts identified by the
!
symbol are critical for
safety. Replace only with part number specified.
B.
In addition to safety, other parts and assemblies
are specified for conformance with regulations
applying to spurious radiation. These must also be
replaced only with specified replacements.
Examples: RF converters, RF cables, noise
blocking capacitors, and noise blocking filters, etc.
C.
Use specified internal wiring. Note especially:
1) Wires covered with PVC tubing
2) Double insulated wires
3) High voltage leads
D.
Use specified insulating materials for hazardous
live parts. Note especially:
1) Insulation tape
2) PVC tubing
3) Spacers
4) Insulators for transistors
E.
When replacing AC primary side components
(transformers, power cord, etc.), wrap ends of
wires securely about the terminals before
soldering.
F.
Observe that the wires do not contact heat
producing parts (heat sinks, oxide metal film
resistors, fusible resistors, etc.).
G.
Check that replaced wires do not contact sharp
edges or pointed parts.
H.
When a power cord has been replaced, check that
5 - 6 kg of force in any direction will not loosen it.
I.
Also check areas surrounding repaired locations.
J.
Be careful that foreign objects (screws, solder
droplets, etc.) do not remain inside the set.
K.
When connecting or disconnecting the internal
connectors, first, disconnect the AC plug from the
AC outlet.
Summary of Contents for D-R410KU
Page 35: ...1 11 4 AV 2 4 Schematic Diagram E7K7ASCAV2 NOTE BOARD MEANS PRINTED CIRCUIT BOARD ...
Page 36: ...1 11 5 E7K7ASCAV3 AV 3 4 Schematic Diagram NOTE BOARD MEANS PRINTED CIRCUIT BOARD ...
Page 37: ...1 11 6 E7K7ASCAV4 AV 4 4 Schematic Diagram NOTE BOARD MEANS PRINTED CIRCUIT BOARD ...
Page 45: ...1 11 14 DVD Main 6 7 Schematic Diagram E7K7ASCD6 NOTE BOARD MEANS PRINTED CIRCUIT BOARD ...
Page 47: ...1 11 16 BE7K2AF01011A BOARD AV Top View NOTE BOARD MEANS PRINTED CIRCUIT BOARD ...
Page 56: ...1 14 3 R5NTI Push close 0 08 V 0 02 s Push Close detection Threshold level ...
Page 66: ......