1-4-4
DVDN_SN
Instructions for Handling Semi-
conductors
Electrostatic breakdown of the semi-conductors may
occur due to a potential difference caused by
electrostatic charge during unpacking or repair work.
1. Ground for Human Body
Be sure to wear a grounding band (1 M
Ω
) that is
properly grounded to remove any static electricity that
may be charged on the body.
2. Ground for Workbench
Be sure to place a conductive sheet or copper plate
with proper grounding (1 M
Ω
) on the workbench or
other surface, where the semi-conductors are to be
placed. Because the static electricity charge on
clothing will not escape through the body grounding
band, be careful to avoid contacting semi-conductors
with your clothing.
<Incorrect>
BOARD
Grounding Band
Conductive Sheet or
Copper Plate
1M
Ω
1M
Ω
<Correct>
BOARD
Summary of Contents for D-R410KU
Page 35: ...1 11 4 AV 2 4 Schematic Diagram E7K7ASCAV2 NOTE BOARD MEANS PRINTED CIRCUIT BOARD ...
Page 36: ...1 11 5 E7K7ASCAV3 AV 3 4 Schematic Diagram NOTE BOARD MEANS PRINTED CIRCUIT BOARD ...
Page 37: ...1 11 6 E7K7ASCAV4 AV 4 4 Schematic Diagram NOTE BOARD MEANS PRINTED CIRCUIT BOARD ...
Page 45: ...1 11 14 DVD Main 6 7 Schematic Diagram E7K7ASCD6 NOTE BOARD MEANS PRINTED CIRCUIT BOARD ...
Page 47: ...1 11 16 BE7K2AF01011A BOARD AV Top View NOTE BOARD MEANS PRINTED CIRCUIT BOARD ...
Page 56: ...1 14 3 R5NTI Push close 0 08 V 0 02 s Push Close detection Threshold level ...
Page 66: ......