-28-
5.12
System Error No. detailed list
[Reproduction prohibited]
No.
Error Detail
Cause
SYSTEM ERROR 03
Setting save error
The setting value failed to be saved in Flash
ROM.
SYSTEM ERROR 05
Software interruption
It is possible to be displayed if program is
wrong.
SYSTEM ERROR 06
Undefined command
It is running other than the program area, or
the program area is destroyed.
SYSTEM ERROR 07
Pre-fetch abort
It accessed to an area without memory
implemented by command pre-fetch.
SYSTEM ERROR 08
Data abort
It accessed to an area without memory
implemented by data access.
SYSTEM ERROR 13
Occur exceptionally other than
user’s request reboot.
It is possible to be displayed (for example, if
program is wrong).
SYSTEM ERROR 20
C/G1 error
ANK CG has not been downloaded.
SYSTEM ERROR 21
C/G2 error
Kanji has not been downloaded.
SYSTEM ERROR 30
WLAN I/F(SDIO) initialization error
Interface initialization of the connection
portion (SDIO) with WLAN module is failed.
SYSTEM ERROR 31
WLAN module initialization error
WLAN module doesn’t respond. It failed in
parameter setting.
SYSTEM ERROR 32
WLAN reception error
It failed to receive data from the module.
SYSTEM ERROR 33
WLAN transmission error
It failed to transmit data to the module.
SYSTEM ERROR 34
WLAN I/F(UART) initialization
error
Interface initialization of the connection
portion (UART) with WLAN module is failed.
SYSTEM ERROR 35
WLAN module F/W is not equipped
SDIO can’t initialize. WLAN F/W has not been
downloaded to the printer.
SYSTEM ERROR 36
WLAN other error
Illegal interrupt occurred on SDIO.
SYSTEM ERROR 40
Charging IC setting error
A command about charging IC has been sent,
but it was not received successfully.
SYSTEM ERROR 41
Battery wrong insertion error
Install high rate battery to B-FP3D-GS30/40
printer.
SYSTEM ERROR 43
Charge IC connection timeout
Timeout occurs at charge IC connection(I2C)
SYSTEM ERROR 50
PLD version error
PLD version is less than V0.4.
SYSTEM ERROR 60
Engine error
PLD SPI data transmission (SET TXTXD data
- Motor Phase current Enable) failed
(time-out count 10000 times).
SYSTEM ERROR 61
Engine error
PLD SPI data transmission (Send Micro Step
Mode - Full command without continues data)
failed (time-out count 10000 times).
SYSTEM ERROR 62
Engine error
PLD SPI
DAC
data transmission failed
(time-out count 10000 times).
SYSTEM ERROR 63
Engine error
PLD SPI data transmission (Send M-Enable
command with continues data) failed (time-out
count 10000 times).
SYSTEM ERROR 64
Engine error
PLD SPI data transmission (Micro Step Mode)
failed (time-out count 10000 times).
SYSTEM ERROR 65
Engine error
DAC output failed to retry-out.
SYSTEM ERROR 66
Engine error
There is an abnormality in LF Motor.
SYSTEM ERROR 67
Engine error
Command queue address error.
SYSTEM ERROR 68
Engine error
Command registration area is invalid.